E.6 Commands
Enter & Exit Fill Mode
F Enter Fill Mode (from General Mode)
xExit Fill Mode (to General Mode) (small ‘x’) Inside the Fill Mode
gStart filling (‘g’ stands for ‘go’) (like input #2 does).
t Terminate an error status (like input #3 does).
e Emergency stop (like input #4 does).
r Get filling(s) report Response Example:
# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= 0
Legend: Filling #1, Actual (=final) weight=40.99, Tare=6.65, Correction Value=0.00,
Fast time=7527 ms, Slow time=2554 ms,
Completion Code=0 (0 is normal, otherwise it’s an error code). Notes:
1.The actual (final) weight (40.99 in the example) is:
*net weight if Auto Tare is selected
*gross weight if Auto Tare is not selected.
2.The reports are accumulated in a FIFO whose size is 30 fillings. That is, only up to last 30 reports are available. Note: The FIFO size (30) is subject to change in the various versions.
3.Please refer also to section 3.3.2.1.4.
FGet fillings summary: Number of normal fillings.
Number of each error type cases for each error type that occurred at least once.
77