Omega Speaker Systems LCIC-WIM-BEN manual Calibration Name 32 characters max

Page 37

 

Calibration Name (32 characters max.)

 

1024-1034

(Organised 3 characters per location; in case the

Float

length is less than 32, the last character is followed by

 

 

 

a binary zero byte.)

 

1053

Analog Output Max Voltage

Float

1054

Analog Output Min Weight

Float

1055

Analog Output Max Weight

Float

1059

Analog Output Mode (0 = Manual, 1 = Auto)

Float

 

Card Serial Number (12 characters max.)

 

1066-1069

(Organised 3 characters per location, in case the

Float

length is less than 12, the last character is followed by

 

 

 

a binary zero byte.)

 

36

Image 37
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application O & the LED Display AppendicesTrouble-shooting General Description IntroductionTypical Applications Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Run the setups of the LCIC-WIM utilities in the folders Setup & RunningUtilities Run a utilityGeneral Calibration UtilityThree stages are Show Data step Pseudo Calibration stepsFive calibration steps are Page Page Page Page Calibrations Library RestoreSave Parameters Calibration Efficiency CE Menu Bar Settings UtilityTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Communication  The address setting takes effect only upon board resetPort Baud RateGet results immediately Activate Auto ZeroMax Zero Min ZeroPage Filter1 Filter2 Decimator FilteringFilling Definition Programming your Application CommandsGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameter Parameter Description Data Number Type ParametersBecomes effective only after a system reset either Calibration Name 32 characters max Start/Stop Communication LCIC-WIM ActiveXGetVariablerVariable Name VariablesCategory Variable Name Description Get Set Variables TableVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Parameter that needs no change FiltersFilteringLevel Integer Fast ModeTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Interpreting the data in a block MiscGeneral Notes about the I/O Appendix a I/O & the LED DisplayDigital Inputs Analog OutputConnections Pin FunctionConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Communication Parameters Appendix D USB, RS232 & RS485Baud Rate RS485 Activate address x x=1, 2, 3, …, 62, 63 RS485 CommandsPage Hello Set the specified RS485 address Read the RS485 address of the active boardRS485 Responses Examples Page Page Board selection by the supplied utilities Introduction Appendix E Fill ModeHardware Inputs Special ModeInput #1 Input #2 Input #3 Input #4 Output #1 Output #2 Output #3 Output #4 Hardware OutputsFilling By = Weight Filling By WeightFilling Parameters TimeAuto Tare Activate Auto Correction Averaging x last fillingsHi Limit Lo LimitStart from filling # … Valid Results LimitsValid Limits ± … % Stabilization Criterion Tare & Stop Filling By = Time Fast Speed ConfigStabilization Criterion Stop Filling Configurations Library LED Display Notations Scale of the displayed weight# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Load Cell Input Appendix F SpecificationsCard does not respond after PC power-on Appendix G Trouble-shootingZero function Appendix H Zero & TareManual Zero Parameter Auto-TarefunctionWARRANTY/DISCLAIMER Temperature