Omega Speaker Systems LCIC-WIM-BEN manual LED Display Notations, Scale of the displayed weight

Page 77

E.5 LED Display Notations

In Fill-mode, the LED display shows the current sub-mode:

m Fill

Manual Fill-mode (input #1 is off)

AutoFill

Auto Fill-mode (input #1 is on)

Likewise, the value shown on the LED display is prefixed by one or two letters:

C Current weight

F Weight during a filling cycle

AActual weight (the resulting final filling weight) SP SetPoint

The scale of the displayed weight

The displayed weight is sometimes gross and sometimes net:

*During a Filling Cycle, and the user selected Auto Tare: The displayed weight is net.

*In all other cases (that is, not during a Filling Cycle, or even during a Filling Cycle but the user did NOT select Auto Tare): The displayed weight is gross.

76

Image 77
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application O & the LED Display AppendicesTrouble-shooting Typical Applications IntroductionGeneral Description Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Run the setups of the LCIC-WIM utilities in the folders Setup & RunningUtilities Run a utilityGeneral Calibration UtilityThree stages are Show Data step Pseudo Calibration stepsFive calibration steps are Page Page Page Page Save RestoreCalibrations Library Parameters Calibration Efficiency CE Menu Bar Settings UtilityTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Communication  The address setting takes effect only upon board resetPort Baud RateGet results immediately Activate Auto ZeroMax Zero Min ZeroPage Filling Definition FilteringFilter1 Filter2 Decimator Programming your Application CommandsGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameter Parameter Description Data Number Type ParametersBecomes effective only after a system reset either Calibration Name 32 characters max Start/Stop Communication LCIC-WIM ActiveXGetVariablerVariable Name VariablesCategory Variable Name Description Get Set Variables TableVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Parameter that needs no change FiltersFilteringLevel Integer Fast ModeTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Interpreting the data in a block MiscGeneral Notes about the I/O Appendix a I/O & the LED DisplayDigital Inputs Analog OutputConnections Pin FunctionConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Communication Parameters Appendix D USB, RS232 & RS485Baud Rate RS485 Activate address x x=1, 2, 3, …, 62, 63 RS485 CommandsPage Hello Set the specified RS485 address Read the RS485 address of the active boardRS485 Responses Examples Page Page Board selection by the supplied utilities Introduction Appendix E Fill ModeInput #1 Input #2 Input #3 Input #4 Special ModeHardware Inputs Output #1 Output #2 Output #3 Output #4 Hardware OutputsFilling By = Weight Filling By WeightFilling Parameters TimeAuto Tare Activate Auto Correction Averaging x last fillingsHi Limit Lo LimitValid Limits ± … % Valid Results LimitsStart from filling # … Stabilization Criterion Tare & Stop Stabilization Criterion Stop Fast Speed ConfigFilling By = Time Filling Configurations Library LED Display Notations Scale of the displayed weight# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Load Cell Input Appendix F SpecificationsCard does not respond after PC power-on Appendix G Trouble-shootingManual Zero Appendix H Zero & TareZero function Parameter Auto-TarefunctionWARRANTY/DISCLAIMER Temperature