E.4.1.4 Stabilization Criterion (Tare & Stop)

At the beginning and at the end of a filling cycle the board waits for the scale to stabilize in order to read its weight. Hence, some stability criterion is required. The board requires that all readings within ‘Delta Time’ will be inside a range whose width is ‘Delta Weight’, both at the beginning (Tare) and at the end (Stop) of the filling cycle. The waiting for that stabilization is limited by ‘Timeout’, causing an error situation in case of failure.

Delta Weight

See the description above.

Delta Time

See the description above.

Stabilization Timeout

See the description above.

Impacts

The system copes with impacts and automatically resumes the filling in case the current weight – after stabilization – is less than the current setpoint.

E.4.1.5 Lazy Filling

Activate

When checked, the board will identify too slow filling, thus reporting an error earlier than the ‘Timeout’ check would do.

73

Image 74
Contents LCIC-WIM-BEN Servicing North America Table of Contents Programming your Application Appendices O & the LED DisplayTrouble-shooting Typical Applications IntroductionGeneral Description Installing the board in the PC Page After a while, you’ll have this display Click ‘Finish’ Utilities Setup & RunningRun the setups of the LCIC-WIM utilities in the folders Run a utilityThree stages are Show Data step Calibration UtilityGeneral Pseudo Calibration stepsFive calibration steps are Page Page Page Page Save RestoreCalibrations Library Parameters Calibration Efficiency CE Settings Utility Menu BarTools / Analog Output Tools / Baud Rate for SCI port Tools / General Setpoints Port  The address setting takes effect only upon board resetCommunication Baud RateGet results immediately Max Zero Auto ZeroActivate Min ZeroPage Filling Definition FilteringFilter1 Filter2 Decimator Commands Programming your ApplicationGet a single reading RS485 Address selection, setting & reading Misc Summary of Weight & A/D Reading Commands Parameters Parameter Parameter Description Data Number TypeBecomes effective only after a system reset either Calibration Name 32 characters max LCIC-WIM ActiveX Start/Stop CommunicationVariables GetVariablerVariable NameVariables Table Category Variable Name Description Get SetVariables Table cont’d AnalogOutputM = Manual, 1 = Auto Internal updates there will be a Filters Parameter that needs no changeFast Mode FilteringLevel IntegerTransmission sends blocks of information Stage How to work with the Fast Mode in VB using the ActiveX Misc Interpreting the data in a blockDigital Inputs Appendix a I/O & the LED DisplayGeneral Notes about the I/O Analog OutputPin Function ConnectionsConnecting External Devices to the Inputs LCIC-WIM I/O & Analog Out LED Display Appendix B Scaling the Load Cell Input Appendix C Load Cell Connections Appendix D USB, RS232 & RS485 Communication ParametersBaud Rate RS485 RS485 Commands Activate address x x=1, 2, 3, …, 62, 63Page Hello Read the RS485 address of the active board Set the specified RS485 addressRS485 Responses Examples Page Page Board selection by the supplied utilities Appendix E Fill Mode IntroductionInput #1 Input #2 Input #3 Input #4 Special ModeHardware Inputs Hardware Outputs Output #1 Output #2 Output #3 Output #4Filling Parameters Filling By WeightFilling By = Weight TimeHi Limit Auto Correction Averaging x last fillingsAuto Tare Activate Lo LimitValid Limits ± … % Valid Results LimitsStart from filling # … Stabilization Criterion Tare & Stop Stabilization Criterion Stop Fast Speed ConfigFilling By = Time Filling Configurations Library Scale of the displayed weight LED Display Notations# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= Get current status small ‘s’ Response Example Error Codes Appendix F Specifications Load Cell InputAppendix G Trouble-shooting Card does not respond after PC power-onManual Zero Appendix H Zero & TareZero function Auto-Tarefunction ParameterWARRANTY/DISCLAIMER Temperature