4.3.4 Fast Mode
(The Fast Mode is not available with RS485.)
During the Fast Mode there is auto high speed transmission of weight readings to the communication. About the transmission rate, refer to the ‘Fast Mode’ square in the variables table above.
At the end, a ‘timer stamp’ is appended. Its value is the time elapsed from start of transmission until end of transmission, in ms.
The readings that are returned in this mode are always integers and they equal the actual weight multiplied by 1, 10, 100, 1000 or 10000, depending upon the resolution setting. So, although the readings are integers, due to that multiplication the original precision is maintained. The readings are not rounded to the resolution. For example, if the resolution is 0.05, then the readings transmitted by the board will be multiplied by 100, so that ‘123’ will represent ‘1.23’.
Start_Fast_Mode(Filtering_Level)
Starts the Fast Mode.
Note: During the Fast Mode the LED Display is not updated.
Filtering_Level (Integer):
1 = Supply readings after Filter1.
2 = Supply readings after Filter2.
Stop_Fast_Mode()
Stops the Fast Mode.
(A timer stamp is appended. Its value is the time elapsed from start of transmission until end of transmission, in ms.)
44