Multi-Tech Systems BA-Series manual Power

Page 10

MultiModemBA User Guide

Fax Modulations

V.21CH2 FSK at 300 bps, V.27ter DPSK at 4800 and 2400 bps,

 

V.29 QAM at 9600 and 7200 bps, V.17 TCM at 14400, 12000, 9600,

 

and 7200 bps

Transmit Level

-11dBm (dial-up), -9 or -15 dBm (leased-line); dBm level selectable

 

with DIP-Switch #3 in leased line setting

Frequency Stability

±0.01%

Connectors

One DB-25 RS-232C connector; two RJ11 for phone line/telephone

 

set; power.

Diagnostics

Power-on Self Test, Local Analog Loop, Local Digital Loop, Remote

 

Digital Loop, Back-to-Back Test.

Indicators

LEDs for Transmit Data, Receive Data, Carrier Detect, Speed

 

Indicators, Off Hook, Terminal Ready, Error Correction, Fax, and

 

Error

Controls

Toggle switches for Voice/Data with Originate or Answer, Power On/

 

Off; and DIP Switches for various modem options.

Speaker

Speaker for call progress monitoring

Operating Temperature

0° to 50° C (32° to 120° F)

Power Requirements

115 Volts AC, 60Hz, 0.3amp (2-prong outlet-mounted transformer)

 

240V/50Hz optional (International).

Dimensions

6.150" x 9.00" x 1.375"

 

15.6 cm x 22.9 cm x 3.5 cm

Weight

1.6 pounds/0.72 Kg (without transformer)

 

2.6 pounds/1.18Kg (with transformer)

Limited Warranty

Five Years

1.6Power

Power is supplied through an AC power transformer terminated with a standard two-prong plug. The transformer supplies low voltage AC to the modem, and plugs into any conventional 115 volt AC, 60 Hz, two-prong power outlet (240 volts AC, 50Hz, .3 Amp for International modems). The power transformer supplied with the modem is the only one that should be used. Use of any other transformer could cause damage to the modem. A Power On/Off switch is located on the back of the modem.

10

Image 10
Contents User Guide User Guide Record of RevisionsContents Index 106 Introduction and Description How To Use This Manual IntroductionDIP-Switches Modem FeaturesCallback and Remote Configuration Warranty, Service & Technical Support1 2834 Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834 LED DisplayControls on PC Board Installation and Connection What is in Your Modem Package? InstallationInstallation and Connection Safety WarningsInstallation Procedure Step ProcedureInstalling Data Communications Software MultiModemBA/BAI ConnectionsSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem AT &F X4 S0=0 MConfiguring Software for the Remote System Changing Default ParametersConfiguring Software for Your Computer Other ParametersTerminal Emulation File Transfer ProtocolsCommand Mode AT Command Editing Functional ModesSummary of AT Commands Command ModeStore Modem Configure Data Multi-Tech Result Codes Result CodesStandard AT Result Codes Continuous Redial not used in BAI a or Dialing Commands Dialing Action CommandsDial Command D Dialing a Stored Number NVoice/Data Dialing $VD Dial Modifier CommandsDTR Dialing $D Pulse or Tone Dial P TSet Pulse Dial Ratios &P Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingCalling Card Detect Tones $ Phone Number Memory CommandsFlash On Hook Quiet Answer @Number Linking NN Configuration and Default Storage CommandsListing Numbers Stored in Memory L Async/Sync Mode Switching &M Loading Factory Defaults &FModem Reset Z Unix Uucp Spoofing $SPResult Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Phone Line Conditioning CommandsGuard Tones Not Used in BAI Models &G Bell/V.21 Tone Enable/Disable Trelis Coded Modulation #TFallback Modes When On-Line #F Phone Line Monitoring Speaker MCleardown at Disconnect &CD 7 RS-232C Interface Control CommandsEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Set Ready Control &S Data Terminal Ready Control &DCTS Control &R CTS/RTS Interaction Control &RFError Correction Commands Enable/Disable Auto Reliable Fallback Character $F Auto-Reliable Buffering $AError Correction/300bps $E Flow Control CommandsRetransmit Count $R Xon/Xoff Flow Control &E5 Hardware Flow Control &E4Xon/Xoff Pass-Through &E7 Hewlett-Packard ENQ/ACK Pacing &E9 Normal Mode Modem Flow Control On &E11Send Xon/Xoff Characters #X Terminal/Computer Initiated Pacing &E13Enq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Parity Selection #PSpeed Conversion $BA Speed Conversion CommandsModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Force Answer Mode a Off Hook HEnable/Disable Reading of Line Probe Information Commands Line Probe CommandsExiting Command Mode, Going Back On-Line O Format of Line Probe Graph or Table CommandsRegisters Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS17 Changing Break Time S15 Callback Time DelayS16 Callback Attempts S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS30 Inactivity Timer S26 Failed Password AttemptsS29 Local Inactivity Timer S32 Time Elapse for Escape SequenceS37 Time Between DTR Active and Modem On-Hook Reading and Assigning S-Register ValuesS36 Time Between DTR Inactive and Modem Off-Hook S48 Program V.34bis Connect Speeds 2834 Series onlyExamples of Assigning Values AT Command and S-Register SummaryExamples of Reading Values Callback Security and Remote Configuration Callback Feature Description Remote Configuration DescriptionTo turn your modems Callback Security feature on and off To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#DB2CR or AT#DB1CR Callback Operational Sequence Procedures Remote Configuration ProceduresCallback Security and Remote Configuration Remote Configuration Operation Procedures StepProcedureChange Login Password Remote Configuration and Callback Security AT CommandsCallback Security Enable/Disable AT#I=yyyyyyyyyyCRRemote Configuration/Callback Security S-Registers Local Inactivity Timer S29 DIP-Switch Settings DIP-Switch Option Settings PC BoardSwitch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP DIP-Switch SettingsMultiModemBA User Guide = Down Down Speaker Volume Control Switch #16 Reserved for Future UseRecording Option Configurations Switch Function Position EffectDIP Switches #13-14 DIP Switches #15-16Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Upgrade Overview Appendix a Upgrading Your Modem’s FirmwareDownload the Upgrade File Upgrade the Modem’s Firmware None of the LEDs Light When the Modem Is On Appendix B TroubleshootingModem Does Not Respond to Commands Appendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Appendix C AT Command Summary Apendix C AT Command SummaryCommand Values Description MultiModemBA User Guide Command Values Description SN d$Fn RF n $SBn Break Atcr Callback Security/Remote Configuration Command Summary Command Description #Ixxxxxxxxxx Password Command Summary#Syyyyyyyyyy 25bis Commands Appendix D V.25bis Operation Delayed and Forbidden Numbers25bis Operation 25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Appendix D V.25bis OperationChange Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandItaly DTR Dialing $D CommandITU V.25bis Country Specific Information SwitzerlandBelgium Appendix E MultiModemBA Cables AustriaFrance SingaporeAppendix E MultiModemBA Cables Figure E-1. RS232 Cable IBM PCAppendix F Regulatory Information Appendix F Regulatory Information FCC PartFCC Part 68 Telecom Industry CanadaCanadian Limitations Notice 104International Modem Restrictions EMC, Safety, and R&TTE Directive Compliance105 Index 106Index 107PBX/CBX Disconnect Drop Time for DSR/CTS/CD53 108109