Multi-Tech Systems BA-Series manual Callback Feature Description, Remote Configuration Description

Page 58

MultiModemBA User Guide

6.1Introduction

This chapter describes how the MultiModem’s Callback and Remote Configuration features operate. These features use a multilevel security system, which involves the use of LOGIN Passwords, Setup Passwords and Remote Escape Characters.

The primary level security code is the modem’s LOGIN Password. Once this password is entered, other passwords can be used. For instance, entering the LOGIN Password will allow you to enter the Setup Password, which, in turn, allows you to enter Callback Passwords and dial back phone numbers. Callback Passwords tell your modem what dial back phone number to call.

The Remote Escape Character is the key to using the Remote Configuration feature. The Remote Escape Character lets you enter Command mode via a remote call, so that you can enter AT commands just as if you were locally connected. You must also enter your modem’s Setup Password. The Remote Escape Character is contained in S-Register S13.

6.2Callback Feature Description

The Callback feature protects your network from unauthorized access and helps control long distance costs. By use of Callback Passwords and dial back phone numbers, you can have your modem "dial back" remote locations immediately after being called. A special command (Enable Callback #DB) turns your modem into a Callback security modem. The Callback Password/Phone number entry is protected by two-level security (your modem's LOGIN Password and Set-Up Password) that keeps unauthorized personnel from changing parameters. When you first get your modem, you need to change both security level codes to your unique settings.

The Callback Passwords and dial back phone numbers are in a special Callback Password/dial back phone number memory (30 numbers long). You use the modem's LOGIN Password and the Set-Up Password plus special Callback commands to access this memory. The memory is thirty numbers long and replaces your modem's normal phone number memory.

Each number is 35 characters long and can contain commands as well as phone numbers. You need to set up your modem with the numbers and codes as part of the dial back initialization procedures. Your modem will also remember if the incoming call was reliable or not, and make the call back accordingly.

6.3Remote Configuration Description

The Remote Configuration feature is a network management tool that allows you to configure modems remotely. This means you could configure modems anywhere in your network from one location without having to visit the sites or rely on remote users to follow your instructions. With Remote Configuration, which is protected by two level security, you can download new parameters, program new V.42 capabilities and implement new features. Remote Configuration also makes troubleshooting a remote location a lot easier.

The way Remote Configuration works is that S-Register S13 has been set up to contain the special Remote Configuration escape code. When calling a Remote Configuration equipped modem, you enter the proper Remote Escape code to enable entering your Set up Password. After entering it, you can then execute AT commands as if you were connected locally. If you set S-Register S13 to zero, Remote Configuration is disabled.

6.3.1Initial Setup Procedures for Callback and Remote Configuration.

Your modem was shipped with a default LOGIN Password and Setup Password (LOGIN=MULTI- TECH and Set-up=MODEMSETUP) so that you have access to the features used for configuring the modem. Because the defaults are in the modem owner’s manual, and anyone can find out what they are, you should change the codes as the first step of your initialization procedure.

58

Image 58
Contents User Guide User Guide Record of RevisionsContents Index 106 Introduction and Description How To Use This Manual IntroductionDIP-Switches Modem FeaturesCallback and Remote Configuration Warranty, Service & Technical Support1 2834 Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834 LED DisplayControls on PC Board Installation and Connection What is in Your Modem Package? InstallationInstallation and Connection Safety WarningsInstallation Procedure Step ProcedureInstalling Data Communications Software MultiModemBA/BAI ConnectionsSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem AT &F X4 S0=0 MConfiguring Software for the Remote System Changing Default ParametersConfiguring Software for Your Computer Other ParametersTerminal Emulation File Transfer ProtocolsCommand Mode AT Command Editing Functional ModesSummary of AT Commands Command ModeStore Modem Configure Data Multi-Tech Result Codes Result CodesStandard AT Result Codes Continuous Redial not used in BAI a or Dialing Commands Dialing Action CommandsDial Command D Dialing a Stored Number NVoice/Data Dialing $VD Dial Modifier CommandsDTR Dialing $D Pulse or Tone Dial P TSet Pulse Dial Ratios &P Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingCalling Card Detect Tones $ Phone Number Memory CommandsFlash On Hook Quiet Answer @Number Linking NN Configuration and Default Storage CommandsListing Numbers Stored in Memory L Async/Sync Mode Switching &M Loading Factory Defaults &FModem Reset Z Unix Uucp Spoofing $SPResult Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Phone Line Conditioning CommandsGuard Tones Not Used in BAI Models &G Bell/V.21 Tone Enable/Disable Trelis Coded Modulation #TFallback Modes When On-Line #F Phone Line Monitoring Speaker MCleardown at Disconnect &CD 7 RS-232C Interface Control CommandsEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Set Ready Control &S Data Terminal Ready Control &DCTS Control &R CTS/RTS Interaction Control &RFError Correction Commands Enable/Disable Auto Reliable Fallback Character $F Auto-Reliable Buffering $AError Correction/300bps $E Flow Control CommandsRetransmit Count $R Xon/Xoff Flow Control &E5 Hardware Flow Control &E4Xon/Xoff Pass-Through &E7 Hewlett-Packard ENQ/ACK Pacing &E9 Normal Mode Modem Flow Control On &E11Send Xon/Xoff Characters #X Terminal/Computer Initiated Pacing &E13Enq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Parity Selection #PSpeed Conversion $BA Speed Conversion CommandsModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Force Answer Mode a Off Hook HEnable/Disable Reading of Line Probe Information Commands Line Probe CommandsExiting Command Mode, Going Back On-Line O Format of Line Probe Graph or Table CommandsRegisters Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS17 Changing Break Time S15 Callback Time DelayS16 Callback Attempts S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS30 Inactivity Timer S26 Failed Password AttemptsS29 Local Inactivity Timer S32 Time Elapse for Escape Sequence S37 Time Between DTR Active and Modem On-Hook Reading and Assigning S-Register Values S36 Time Between DTR Inactive and Modem Off-Hook S48 Program V.34bis Connect Speeds 2834 Series onlyExamples of Assigning Values AT Command and S-Register SummaryExamples of Reading Values Callback Security and Remote Configuration Callback Feature Description Remote Configuration DescriptionTo turn your modems Callback Security feature on and off To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#DB2CR or AT#DB1CR Callback Operational Sequence Procedures Remote Configuration ProceduresCallback Security and Remote Configuration Remote Configuration Operation Procedures StepProcedureChange Login Password Remote Configuration and Callback Security AT CommandsCallback Security Enable/Disable AT#I=yyyyyyyyyyCRRemote Configuration/Callback Security S-Registers Local Inactivity Timer S29 DIP-Switch Settings DIP-Switch Option Settings PC BoardSwitch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP DIP-Switch SettingsMultiModemBA User Guide = Down Down Speaker Volume Control Switch #16 Reserved for Future UseRecording Option Configurations Switch Function Position EffectDIP Switches #13-14 DIP Switches #15-16Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Upgrade Overview Appendix a Upgrading Your Modem’s FirmwareDownload the Upgrade File Upgrade the Modem’s Firmware None of the LEDs Light When the Modem Is On Appendix B TroubleshootingModem Does Not Respond to Commands Appendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Appendix C AT Command Summary Apendix C AT Command SummaryCommand Values Description MultiModemBA User Guide Command Values Description SN d$Fn RF n $SBn Break Atcr Callback Security/Remote Configuration Command Summary Command Description #Ixxxxxxxxxx Password Command Summary#Syyyyyyyyyy 25bis Commands Appendix D V.25bis Operation Delayed and Forbidden Numbers25bis Operation 25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Appendix D V.25bis OperationChange Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandItaly DTR Dialing $D CommandITU V.25bis Country Specific Information SwitzerlandBelgium Appendix E MultiModemBA Cables AustriaFrance SingaporeAppendix E MultiModemBA Cables Figure E-1. RS232 Cable IBM PCAppendix F Regulatory Information Appendix F Regulatory Information FCC PartFCC Part 68 Telecom Industry CanadaCanadian Limitations Notice 104International Modem Restrictions EMC, Safety, and R&TTE Directive Compliance105 Index 106Index 107PBX/CBX Disconnect Drop Time for DSR/CTS/CD53 108109