MultiModemBA User Guide
Switch #10
Leased
(Asynchronous/Synchronous Mode/Leased
The modem operates in either
= | Switch #10 UP | |
Leased Line Operation | = | Switch #10 DOWN |
Factory Default Setting | = | UP |
Switch #11
"AT"
In Asynchronous mode, you can set the modem to respond with Result Codes according to the
"AT" Responses (&Q1) | = | Switch #11 UP |
= | Switch #11 DOWN | |
Factory Default Setting | = | DOWN |
Switch #11
Internal/External Clocking
(Synchronous Mode/Leased
In Synchronous mode, the transmit clock can be supplied by the DTE on pin 24 of the
External Clock (pin 24) | = | Switch #11 UP |
Internal Clock (pins 15/17) | = | Switch #11 DOWN |
Factory Default Setting | = | DOWN |
Switch #12
Asynchronous/Synchronous Operation
(Asynchronous/Synchronous Mode/Leased
The modem can operate in either Asynchronous mode or Synchronous mode. In Synchronous mode, start and stop bits are eliminated. The modem's internal clock circuits on the
Synchronous Operation | = | Switch #12 UP |
Asynchronous Operation | = | Switch #12 DOWN |
Factory Default Setting | = | DOWN |
70