Multi-Tech Systems BA-Series manual PBX/CBX Disconnect Drop Time for DSR/CTS/CD53, 108

Page 108

MultiModemBA User Guide

Pause Time for Comma

51

PBX/CBX Disconnect Drop Time for DSR/CTS/CD53

PBX/CBX systems

53

Power

10

Power supply

82

Program V.34bis Connect Speeds

55

Program V34 Connect Speeds

55

Protocols

20, 85

Pulse or Tone Dial (P T)

28

Q

 

Quiet Answer (@)

30

R

Reading of Line Probe Information Commands . 48

registering your product

76

Reliable Mode (&E2)

38

Remote Configuration Character

63

Remote Configuration Escape Character

52

Remote System Configuration

19

replacement parts

77

Request To Send Forced

69

Result codes

18, 84

Result Codes Enable/Disable and No Response (Q)

33

 

Result Codes Verbose/Terse (V)

33

Retransmit Count ($R)

40

Return Character

50

Return character

18

Return to Command Mode After Dial Execution (;)29

Reverse the Mode of Operation (R)

29

Rings Which Have Occurred

..............................

50

S

 

 

S-Registers

 

 

S3

18

Safety Warning Telecom

15

SDLC/BSC Option

67

Send Xon/Xoff Characters (#X)

42

Serial cable

83

Serial port

18,

19, 83

Serial Port Baud Rate ($SB)

..............................

45

serial ports

45

servicing your modem

104

Sessions

18

Set Pulse Dial Ratios (&P)

29

Signal Strength information

48

Signal to Noise Ratio information (SNR)

48

Slave Clocking

69

Slow File Transfer

85

smart dialing

34

Speaker

10

Speed Conversion ($BA)

44

Speed Switches

71

Storing Phone Numbers (D...

N)

30

Summary

56

Synchronous Transmit Clock Select (&X)

32

T

 

Telephone line

84

Terminal mode

82

Terminal/Computer Initiated Pacing (&E13)

....... 42

Testing

82, 84

self-test

82

Time Elapse for Escape Sequence

54

Time for Carrier (Abort Timer)

51

Tone Dialing: Tone Spacing and Duration

52

Tradename

9

Transmission speed

19

Transmit Level

10

Two Wire Leased Line Connection

102

U

 

UART

45

UARTs

19

16450

19

16550

19, 85

8250

19

8250A

19

Unix UUCP Spoofing

68

Unix UUCP Spoofing ($SP)

32

upgrading the modem

79–105

V

 

V.25bis Mode AT Commands

97

V.25bis AT Commands

98

V.25bis Operation

96

V.25bis Responses (Result Codes)

98

V.25bis Set-Up and Initialization

97

V.42 Mode Select (#L)

38

V.42bis

19

W

 

Wait for New-Dial-Tone (W)

29

Wait Time for Dial Tone

51

"Wait-for-Carrier"

22

warranty

104

Weight

10

Windows 3.1

85

serial port driver

85

Windows 95 Autodetect Inquiry Command (I9) .. 46

Windows 95 HyperTerminal

85

X

 

Xmodem

85

Xon/Xoff Flow Control (&E5)

41

Xon/Xoff Pass-Through (&E7)

41

Xon/Xoff Pass-Through Commands

43

108

Image 108
Contents User Guide User Guide Record of RevisionsContents Index 106 Introduction and Description How To Use This Manual IntroductionModem Features Callback and Remote ConfigurationDIP-Switches Warranty, Service & Technical Support1 2834 Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834 LED DisplayControls on PC Board Installation and Connection What is in Your Modem Package? InstallationSafety Warnings Installation ProcedureInstallation and Connection Step ProcedureInstalling Data Communications Software MultiModemBA/BAI ConnectionsSoftware Configuration and Modem Basics Configuring Your Software Configuring Software for Your ModemPC Initialization Strings AT &F X4 S0=0 MChanging Default Parameters Configuring Software for Your ComputerConfiguring Software for the Remote System Other ParametersTerminal Emulation File Transfer ProtocolsCommand Mode AT Command Editing Functional ModesSummary of AT Commands Command ModeStore Modem Configure Data Result Codes Multi-Tech Result CodesStandard AT Result Codes Dialing Commands Dialing Action Commands Dial Command DContinuous Redial not used in BAI a or Dialing a Stored Number NDial Modifier Commands DTR Dialing $DVoice/Data Dialing $VD Pulse or Tone Dial P TReturn to Command Mode After Dial Command Execution Reverse the Mode of Operation RSet Pulse Dial Ratios &P Automatic Pauses in DialingPhone Number Memory Commands Flash On HookCalling Card Detect Tones $ Quiet Answer @Configuration and Default Storage Commands Number Linking NNListing Numbers Stored in Memory L Loading Factory Defaults &F Modem Reset ZAsync/Sync Mode Switching &M Unix Uucp Spoofing $SPCommand Response Result Code Commands Echo Command Mode Characters EResult Codes Enable/Disable and No Response Answer Q Result Codes Multi-Tech or Standard AT &QPhone Line Conditioning Commands Result Codes Basic and Extended and Call Progress SelectionGuard Tones Not Used in BAI Models &G Enable/Disable Trelis Coded Modulation #T Fallback Modes When On-Line #FBell/V.21 Tone Phone Line Monitoring Speaker M7 RS-232C Interface Control Commands Enable/Disable Lowspeed Fast Connect $FCCleardown at Disconnect &CD Auto Speed Detect #AData Terminal Ready Control &D CTS Control &RData Set Ready Control &S CTS/RTS Interaction Control &RFError Correction Commands Enable/Disable Auto Reliable Fallback Character $F Auto-Reliable Buffering $AFlow Control Commands Error Correction/300bps $ERetransmit Count $R Hardware Flow Control &E4 Xon/Xoff Flow Control &E5Xon/Xoff Pass-Through &E7 Normal Mode Modem Flow Control On &E11 Send Xon/Xoff Characters #XHewlett-Packard ENQ/ACK Pacing &E9 Terminal/Computer Initiated Pacing &E13Normal/Auto-Reliable/Reliable Mode Commands Xon/Xoff Pass-Through CommandsEnq/Ack Pacing Commands Parity Selection #PSpeed Conversion Commands Speed Conversion $BAModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Force Answer Mode a Off Hook HLine Probe Commands Exiting Command Mode, Going Back On-Line OEnable/Disable Reading of Line Probe Information Commands Format of Line Probe Graph or Table CommandsRegisters Number of Rings Until Modem Answers Rings Which Have OccurredEscape Code Character Return CharacterTime for Carrier Abort Timer Line Feed CharacterBackspace Character Wait Time for Dial ToneS10 Carrier Loss Disconnect Delay Time S13 Remote Configuration Escape CharacterCarrier Detect Response Time S11 Tone Dialing Tone Spacing and DurationS15 Callback Time Delay S16 Callback AttemptsS17 Changing Break Time S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS26 Failed Password Attempts S29 Local Inactivity TimerS30 Inactivity Timer S32 Time Elapse for Escape SequenceReading and Assigning S-Register Values S36 Time Between DTR Inactive and Modem Off-HookS37 Time Between DTR Active and Modem On-Hook S48 Program V.34bis Connect Speeds 2834 Series onlyAT Command and S-Register Summary Examples of Assigning ValuesExamples of Reading Values Callback Security and Remote Configuration Callback Feature Description Remote Configuration DescriptionTo change your Remote Configuration feature status To turn your modems Callback Security feature on and offTo set parity of the password/message prompt AT#DB2CR or AT#DB1CR Remote Configuration Procedures Callback Security and Remote ConfigurationCallback Operational Sequence Procedures Remote Configuration Operation Procedures StepProcedureRemote Configuration and Callback Security AT Commands Callback Security Enable/DisableChange Login Password AT#I=yyyyyyyyyyCRRemote Configuration/Callback Security S-Registers Local Inactivity Timer S29 DIP-Switch Settings DIP-Switch Option Settings PC BoardSwitch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP DIP-Switch SettingsMultiModemBA User Guide = Down Down Speaker Volume Control Switch #16 Reserved for Future UseRecording Option Configurations Switch Function Position EffectDIP Switches #13-14 DIP Switches #15-16Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsReplacement Parts Technical SupportInternet Sites Country TelephoneAppendixes Upgrade Overview Appendix a Upgrading Your Modem’s FirmwareDownload the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting None of the LEDs Light When the Modem Is OnModem Does Not Respond to Commands Appendix B Troubleshooting Modem Dials But Cannot Make a Connection Modem Cannot Connect When Answering Modem Disconnects While On-lineFile Transfer Is Slower Than It Should Be Am Losing DataAm Getting Garbage Characters on the Monitor Apendix C AT Command Summary Appendix C AT Command SummaryCommand Values Description MultiModemBA User Guide Command Values Description SN d$Fn RF n $SBn Break Atcr Callback Security/Remote Configuration Command Summary Password Command Summary Command Description #Ixxxxxxxxxx#Syyyyyyyyyy 25bis Commands Delayed and Forbidden Numbers Appendix D V.25bis Operation25bis Operation 25bis Mode AT Commands 25bis DIP-Switches25bis Set-Up and Initialization Appendix D V.25bis Operation25bis AT Commands Enable/Disable V.25bis Mode $V CommandChange Serial Baud Rate CSP Command 25bis Responses Result CodesDial Phone Number Provided CRN Command Listing Delayed Phone Numbers RLD CommandListing Forbidden Phone Number RLF Command Disregard or Connect to Incoming Calls DIC or CIC CommandDTR Dialing $D Command ITU V.25bis Country Specific InformationItaly SwitzerlandAppendix E MultiModemBA Cables Austria FranceBelgium SingaporeAppendix E MultiModemBA Cables Figure E-1. RS232 Cable IBM PCAppendix F Regulatory Information FCC Part FCC Part 68 TelecomAppendix F Regulatory Information Industry CanadaCanadian Limitations Notice 104EMC, Safety, and R&TTE Directive Compliance International Modem Restrictions105 Index 106Index 107PBX/CBX Disconnect Drop Time for DSR/CTS/CD53 108109