Multi-Tech Systems BA-Series manual DIP-Switch Option Settings, PC Board

Page 66

MultiModemBA User Guide

7.1Introduction

There are several DIP-Switch options on the modem’s printed circuit (PC) board. The DIP-Switches are accessible through a cut-out on the side of the modem. This chapter explains the modem’s printed-circuit board options. Sixteen DIP-Switch settings and the modem's speaker volume control are explained in detail, including all default settings.

Power Switch

Power Jack

LED

 

 

 

 

 

 

 

RS-232/V.24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

OPEN

1

2

3

4

5

6

7

8

9

10 11 12

13 14 15 16

Line Jack Phone Jack

16-position DIP-switch

Figure 7-1. PC Board

7.2DIP-Switch Option Settings

Switch #1

Forced DTR -- "DTR"

(Asynchronous/Synchronous Mode/Leased Line/Dial-Up)

The modem must have a high DTR signal in order to operate. DTR is provided to the modem by the terminal or computer to which it is attached, through pin 20 of the RS-232C/V.24 interface. If your terminal or computer is not providing DTR to the modem, you can force the DTR signal high with DIP- Switch #1.

DTR function normally DTR forced On Factory Default Setting

=Switch #1 UP

=Switch #1 DOWN

=UP

Switch #2

Flow Control - &E4/&E5

(Asynchronous Mode/Leased Line/Dial-Up)

With Hardware Flow Control, the modem uses its RS-232C/V.24 interface to control the flow of data from the computer or terminal to which it is attached. The CTS signal on Pin 5 of the RS-232C/V.24 is brought low to stop the flow of data, and is brought high to restart it. Place DIP-Switch #2 in the UP position to enable Hardware Flow Control (&E4). Xon/Xoff Flow Control (&E5) is another flow control method. Xon/Xoff characters in the data dictate the start and stop of data flow from the computer or terminal. Place DIP-Switch #2 in the DOWN position to select Xon/Xoff Flow Control.

Hardware Flow Control (&E4)

=

Switch #2 UP

Xon/Xoff Flow Control (&E5)

=

Switch #2 DOWN

Factory Default Setting

=

UP

66

Image 66
Contents User Guide User Guide Record of RevisionsContents Index 106 Introduction and Description How To Use This Manual IntroductionDIP-Switches Modem FeaturesCallback and Remote Configuration Warranty, Service & Technical Support1 2834 Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834 LED DisplayControls on PC Board Installation and Connection What is in Your Modem Package? InstallationInstallation and Connection Safety WarningsInstallation Procedure Step ProcedureInstalling Data Communications Software MultiModemBA/BAI ConnectionsSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem AT &F X4 S0=0 MConfiguring Software for the Remote System Changing Default ParametersConfiguring Software for Your Computer Other ParametersTerminal Emulation File Transfer ProtocolsCommand Mode AT Command Editing Functional ModesSummary of AT Commands Command ModeStore Modem Configure Data Result Codes Multi-Tech Result CodesStandard AT Result Codes Continuous Redial not used in BAI a or Dialing Commands Dialing Action CommandsDial Command D Dialing a Stored Number NVoice/Data Dialing $VD Dial Modifier CommandsDTR Dialing $D Pulse or Tone Dial P TSet Pulse Dial Ratios &P Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingCalling Card Detect Tones $ Phone Number Memory CommandsFlash On Hook Quiet Answer @Configuration and Default Storage Commands Number Linking NNListing Numbers Stored in Memory L Async/Sync Mode Switching &M Loading Factory Defaults &FModem Reset Z Unix Uucp Spoofing $SPResult Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QPhone Line Conditioning Commands Result Codes Basic and Extended and Call Progress SelectionGuard Tones Not Used in BAI Models &G Bell/V.21 Tone Enable/Disable Trelis Coded Modulation #TFallback Modes When On-Line #F Phone Line Monitoring Speaker MCleardown at Disconnect &CD 7 RS-232C Interface Control CommandsEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Set Ready Control &S Data Terminal Ready Control &DCTS Control &R CTS/RTS Interaction Control &RFError Correction Commands Enable/Disable Auto Reliable Fallback Character $F Auto-Reliable Buffering $AFlow Control Commands Error Correction/300bps $ERetransmit Count $R Hardware Flow Control &E4 Xon/Xoff Flow Control &E5Xon/Xoff Pass-Through &E7 Hewlett-Packard ENQ/ACK Pacing &E9 Normal Mode Modem Flow Control On &E11Send Xon/Xoff Characters #X Terminal/Computer Initiated Pacing &E13Enq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Parity Selection #PSpeed Conversion Commands Speed Conversion $BAModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Force Answer Mode a Off Hook HEnable/Disable Reading of Line Probe Information Commands Line Probe CommandsExiting Command Mode, Going Back On-Line O Format of Line Probe Graph or Table CommandsRegisters Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS17 Changing Break Time S15 Callback Time DelayS16 Callback Attempts S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS30 Inactivity Timer S26 Failed Password AttemptsS29 Local Inactivity Timer S32 Time Elapse for Escape SequenceS37 Time Between DTR Active and Modem On-Hook Reading and Assigning S-Register ValuesS36 Time Between DTR Inactive and Modem Off-Hook S48 Program V.34bis Connect Speeds 2834 Series onlyAT Command and S-Register Summary Examples of Assigning ValuesExamples of Reading Values Callback Security and Remote Configuration Callback Feature Description Remote Configuration DescriptionTo change your Remote Configuration feature status To turn your modems Callback Security feature on and offTo set parity of the password/message prompt AT#DB2CR or AT#DB1CR Callback Operational Sequence Procedures Remote Configuration ProceduresCallback Security and Remote Configuration Remote Configuration Operation Procedures StepProcedureChange Login Password Remote Configuration and Callback Security AT CommandsCallback Security Enable/Disable AT#I=yyyyyyyyyyCRRemote Configuration/Callback Security S-Registers Local Inactivity Timer S29 DIP-Switch Settings DIP-Switch Option Settings PC BoardSwitch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP DIP-Switch SettingsMultiModemBA User Guide = Down Down Speaker Volume Control Switch #16 Reserved for Future UseRecording Option Configurations Switch Function Position EffectDIP Switches #13-14 DIP Switches #15-16Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Upgrade Overview Appendix a Upgrading Your Modem’s FirmwareDownload the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting None of the LEDs Light When the Modem Is OnModem Does Not Respond to Commands Appendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Apendix C AT Command Summary Appendix C AT Command SummaryCommand Values Description MultiModemBA User Guide Command Values Description SN d$Fn RF n $SBn Break Atcr Callback Security/Remote Configuration Command Summary Password Command Summary Command Description #Ixxxxxxxxxx#Syyyyyyyyyy 25bis Commands Delayed and Forbidden Numbers Appendix D V.25bis Operation25bis Operation 25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Appendix D V.25bis OperationChange Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandItaly DTR Dialing $D CommandITU V.25bis Country Specific Information SwitzerlandBelgium Appendix E MultiModemBA Cables AustriaFrance SingaporeAppendix E MultiModemBA Cables Figure E-1. RS232 Cable IBM PCAppendix F Regulatory Information Appendix F Regulatory Information FCC PartFCC Part 68 Telecom Industry CanadaCanadian Limitations Notice 104EMC, Safety, and R&TTE Directive Compliance International Modem Restrictions105 Index 106Index 107PBX/CBX Disconnect Drop Time for DSR/CTS/CD53 108109