Liebert GXT2-6000RTL630 user manual Main Frame and Electronics, Major Components, Controls

Page 11

Major Components

3.0MAJOR COMPONENTS

The GXT2-6000RTL630 is composed of three major assemblies to provide easier handling, installa- tion, and versatility.

3.1Main Frame and Electronics

This 5U cabinet is shipped without internal batteries to lighten the UPS for easier installation. The internal batteries may be installed after the cabinet has been placed in its final floor or rack position. The Power Distribution box is shipped separately for easier handling of the UPS while being placed in its final position.

Figure 1 GXT2-6000RTL630, front view

Top Trim (2 pieces; tower use only)

Status

!

Indicators

UPStation GXT

& Controls

Lower Bezel &

Battery Access

Door

Upper

Bezel

7

Image 11
Contents Liebert GXT2-6000RTL630 Page Table of Contents Operating Instructions MaintenanceTroubleshooting SpecificationsElectromagnetic Compatibility Important Safety InstructionsPage Glossary of Symbols Introduction System Description Rectifier/Power Factor Correction PFC CircuitBattery Charger InverterDynamic Bypass BatteryDC-to-DC Converter Major Components Top Trim 2 pieces tower use only Status IndicatorsLower Bezel Battery Access Door Upper Main Frame and ElectronicsRelay Card Slot Internal Battery PacksBattery Disconnect External Battery Connector Fans UPS Output Circuit Breaker DB-9 Communication PortConnections Removable Power Distribution BoxBypass To UPS Switch ManualWHAT’S Included Configuration Disk DB-9 port coverAttach Bezels to Top Install the Main CabinetInstallation and Configuration Tower UPS InstallationReturn flanges Retaining Latches Front Innermembers members Rack-Mount UPS InstallationInstalling the Adjustable Rack-Mount Kit-Sold Separately QuantityScrews Apply grease inside Push it into the rack Install the Internal BatteriesUPS or CabinetRemove these screws to release connector Connect the Internal Batteries Using the External ConnectorConnect Input/Output Power Battery Door Captive ScrewsLoosen these three Attach Power Distribution BoxFront of PD-L630 power distribution box Distribution Box Electrical Connections UPSExternal Battery Cabinet Installation Initial START-UP and Electrical Checks What You Will Need GXT2-6000RTL630 Configuration Program FeaturesConfiguration Program Standby/Manual Bypass Button ON/Alarm Silence/Manual Battery Test ButtonControls and Indicators All indicators illuminated for illustration onlyBypass Indicator LED Amber Load Level Indicators 4 Green, 1 AmberBattery Level Indicators 5 Green Fault Indicator LED RedBattery Recharge Mode Normal Mode OperationBattery Mode Operation Bypass Mode OperationDB-9 pin assignment Pin 4 Remote Shutdown on BatteryCommunications Interface Port CommunicationsLiebert’s Ocwebcard DB9 RS232 port covered UPS Intelligent CommunicationsRepo switch connection diagram Remote Emergency Power OffMaintenance Internal BatteryRetaining screw Retaining bracket Internal Battery ReplacementBattery Door Captive Screws 3U Battery Access Door Battery ConnectorsBox to AC Power ConnectionsDisconnect CaptiveReconnect LED status Diagnosis/Audible alarm TroubleshootingIndicator meanings UPS Troubleshooting guideAlarm conditions Troubleshooting guide cont’dBattery run times Auto-Learning Battery Run Times UPS specifications SpecificationsOutput distribution specifications Internal battery specificationsModel Number External battery cabinet specificationsBattery Parameters Page That Ne tIti Ti n