Liebert GXT2-6000RTL630 user manual Introduction

Page 8

Introduction

1.0INTRODUCTION

Congratulations on your choice of the Liebert GXT2-6000RTL630 Uninterruptible Power Supply (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment.

Upon generation, AC power is clean and stable. However, during transmission and distribution it may be subject to voltage sags, spikes or complete power failure that may interrupt computer opera- tions, cause data loss or even damage equipment. The GXT2-6000RTL630 protects equipment from these disturbances.

The GXT2-6000RTL630 comes in a nominal power rating of 6000 VA. Complete model specifications appear at the end of this manual.

The GXT2-6000RTL630 is a compact, on-line UPS. An on-line UPS continuously conditions and regu- lates its output voltage, whether utility power is present or not. It supplies connected equipment with clean sinewave power. Sensitive electronic equipment operates best from sinewave power.

For ease of use, the GXT2-6000RTL630 features a light-emitting diode (LED) display to indicate both load percentage and battery capacity. It also provides self-diagnostic tests, a combination ON/Alarm Silence/Manual Battery Test button, a Standby button, user configurable program, and two levels of alarms when the unit is operating on battery.

The GXT2-6000RTL630 has an interface port for communication between the UPS and a network server or other computer systems. This port provides detailed operating information including volt- ages, currents, and alarm status to the host system when used in conjunction with Liebert Multi- Link™ software. MultiLink software can also remotely control UPS operation.

4

Image 8
Contents Liebert GXT2-6000RTL630 Page Table of Contents Maintenance TroubleshootingSpecifications Operating InstructionsImportant Safety Instructions Electromagnetic CompatibilityPage Glossary of Symbols Introduction Rectifier/Power Factor Correction PFC Circuit Battery ChargerInverter System DescriptionDynamic Bypass BatteryDC-to-DC Converter Top Trim 2 pieces tower use only Status Indicators Lower Bezel Battery Access Door UpperMain Frame and Electronics Major ComponentsInternal Battery Packs Battery Disconnect External Battery ConnectorFans UPS Output Circuit Breaker DB-9 Communication Port Relay Card SlotRemovable Power Distribution Box Bypass To UPS SwitchManual ConnectionsConfiguration Disk DB-9 port cover WHAT’S IncludedInstall the Main Cabinet Installation and ConfigurationTower UPS Installation Attach Bezels to TopRack-Mount UPS Installation Installing the Adjustable Rack-Mount Kit-Sold SeparatelyQuantity Return flanges Retaining Latches Front Innermembers membersScrews Install the Internal Batteries UPS orCabinet Apply grease inside Push it into the rackConnect the Internal Batteries Using the External Connector Connect Input/Output PowerBattery Door Captive Screws Remove these screws to release connectorLoosen these three Attach Power Distribution BoxFront of PD-L630 power distribution box UPS Distribution Box Electrical ConnectionsExternal Battery Cabinet Installation Initial START-UP and Electrical Checks What You Will Need GXT2-6000RTL630 Configuration Program FeaturesConfiguration Program ON/Alarm Silence/Manual Battery Test Button Controls and IndicatorsAll indicators illuminated for illustration only Standby/Manual Bypass ButtonLoad Level Indicators 4 Green, 1 Amber Battery Level Indicators 5 GreenFault Indicator LED Red Bypass Indicator LED AmberNormal Mode Operation Battery Mode OperationBypass Mode Operation Battery Recharge ModePin 4 Remote Shutdown on Battery Communications Interface PortCommunications DB-9 pin assignmentUPS Intelligent Communications Liebert’s Ocwebcard DB9 RS232 port coveredRemote Emergency Power Off Repo switch connection diagramInternal Battery MaintenanceInternal Battery Replacement Battery Door Captive Screws 3U Battery Access DoorBattery Connectors Retaining screw Retaining bracketAC Power Connections DisconnectCaptive Box toReconnect LED status Diagnosis/Audible alarm TroubleshootingIndicator meanings Troubleshooting guide UPSTroubleshooting guide cont’d Alarm conditionsBattery run times Auto-Learning Battery Run Times Specifications UPS specificationsInternal battery specifications Output distribution specificationsModel Number External battery cabinet specificationsBattery Parameters Page Ne t ItiTi n That