Lantronix UDS1100 manual Host List Configuration, To configure the host list, Retry Settings

Page 26

4: Configuration Using Web-Manager

MTU Size

The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is 1400 bytes.

3.When you are finished, click the OK button.

4.On the main menu, click Apply Settings.

Host List Configuration

The UDS1100 scrolls through the host list until it connects to a device listed in the host list table. After a successful connection, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until the next successful connection.

The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an IP address and a port number.

Note: The host list is disabled for Manual and Modem Mode. The unit does not accept a data connection from a remote device when the hostlist option is enabled.

To configure the host list:

1. On the main menu, click Hostlist.

Figure 4-4. Hostlist Settings

2. Enter or modify the following fields:

Retry Settings

Retry Counter

Enter the value for the number of times the UDS1100 should attempt to retry connecting to the host list. The default setting is 3.

UDS1100 User Guide

26

Image 26
Contents UDS1100 User Guide Revisions Copyright & TrademarkContacts Date Rev Comments 900-417Contents Setup Mode Server Configuration Troubleshooting and Contact Information Contents TablesChapter Summary Using This GuidePurpose and Audience Using This Guide Additional DocumentationApplication Examples IntroductionApplications Introduction Protocol Support Additional FeaturesConfiguration Methods Product Information Label Sample Hardware AddressPackage Contents Getting StartedInstalling the UDS To install the unitIP Address Required InformationHardware Address IP Address Subnet Mask GatewayAssigning an IP Address Assigning the IP Address DeviceInstallerInstalling DeviceInstaller Select Assign a specific IP address and click NextTo view the units current settings Accessing the UDS1100 Using DeviceInstallerViewing the Current Configuration Adding the Unit to the Manage ListIP Address on Assigning the IP Address Serial Port Login Next StepGetting Started Configuration Using Web-Manager Accessing UDS1100 Using DeviceInstallerNetwork Configuration Lantronix Web-Manager Automatic IP Address Configuration Static IP Address ConfigurationTo specify how data will be transmitted Server ConfigurationEthernet Configuration Advanced To configure the UDS1100’s device server settingsServer Configuration Retry Settings Host List ConfigurationTo configure the host list To configure the channel’s serial settings Channel 1 ConfigurationSerial Settings Host InformationPack Control Port SettingsChannel Flush Input Buffer Serial to Network Connection Settings TCPTo configure a channel’s TCP settings Flush Output Buffer Network to SerialConnect Mode Passive Connection Connect ProtocolCommon Options Connect Mode Active ConnectionEndpoint Configuration To configure a channel’s UDP settings Connection Settings UDPDisconnect Mode Datagram Mode UDP Connection SettingsApply Settings Apply Factory DefaultsTelnet Connection Configuration via Telnet or Serial Port Setup ModeAccessing Setup Mode To establish a Telnet connectionSerial Port Connection Exiting Setup ModeTo exit setup mode IP Address Setup Mode Server ConfigurationServer Configuration Option Set Gateway IP AddressDhcp Name Change Telnet Configuration PasswordNetmask Number of Bits for Host Part Network Class Host Bits NetmaskSetup Mode Server Configuration Baudrate Setup Mode Channel ConfigurationChannel 1 Option Common I/F Mode Setting Binary Interface ModeMode Option FlowFlow Control Option Hex Connect ModePort Number Port Numbers Reserved forConnect Mode Option Incoming ConnectionResponse Active StartupManual Connection Address Example Datagram Type Modem ModeTo enable the hostlist MessageMeaning No CarrierModem Mode Function Command ATDRemote IP Address Send the Escape Sequence +++ in Modem ModeAuto Increment Source Port Remote PortFlush Mode Buffer Flushing Disconnect Mode OptionPack Control OptionPacking Interval DisConnTime Inactivity TimeoutSend Characters Trailing CharactersChannel Port Password Telnet Terminal TypeTCP Keepalive time in seconds Setup Mode Advanced SettingsExpert Settings Option Enable alternate MAC ARP Cache timeout in secondsDisable Monitor Mode at bootup Http Port NumberDisable Telnet Setup Security Settings OptionDisable Snmp Snmp Community NameDisable Web Server Disable Tftp Firmware UpdateDisable Port 77FE Hex Disable Web SetupExpert Settings Defaults Default Settings OptionChannel 1 Configuration Defaults Security Settings DefaultsSetup Mode Advanced Settings Obtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface ROM FileUsing Tftp Command Line Interface To recover firmwareFirmware Upgrades Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsCommand Command Name Function Response MeaningTroubleshooting and Contact Information LEDsProblems and Error Messages Problem/Message Reason SolutionLock on Technical Support Technical Support Europe, Middle East, and AfricaSerial Port Serial Connector PinoutsConnections and Pinouts DB25 Female Interface RS422 4 wire mode Modem CableNetwork Port Null Modem Cable Lantronix Part NoEthernet Connector Pinouts Power PlugTechnical Specifications Category DescriptionTechnical Specifications Alternative Ways to Assign an IP Address AutoIPARP and Telnet To assign a temporary IP addressDecimal Binary Hex Converting Binary to HexadecimalConversion Table Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index UDS1100 User Guide