5: Configuration via Telnet or Serial Port (Setup Mode)
Figure 5-1. MAC Address
3.To enter Setup Mode, press Enter within 5 seconds. The configuration settings display, followed by the Change Setup menu.
Figure 5-2. Setup Menu Options
4.Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter.
5.To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter.
6.When you are finished, save the new configuration (option 9). The unit reboots.
Serial Port Connection
To configure the unit through a serial connection:
1.Connect a console terminal or PC running a terminal emulation program to your unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
2.Reset the UDS1100 unit by cycling the unit's power (turning the power off and back on). Immediately upon resetting the device, enter three lowercase x characters (xxx).
Note: The easiest way to enter Setup Mode is to hold down the x key at the terminal (or emulation) while resetting the unit. You must do this within three seconds of resetting the UDS1100.
At this point, the screen display is the same as when you use a Telnet connection. To continue, go to step 3 in Telnet Connection, above.
Exiting Setup Mode
To exit setup mode:
You have two options:
To save all changes and reboot the device, select option 9 Save and exit from the Change Setup menu. All values are stored in nonvolatile memory.
To exit the configuration mode without saving any changes or rebooting. select option 8 Exit without save from the Change Setup menu.
UDS1100 User Guide | 36 |