8: Setup Mode: Advanced Settings
Default Settings (Option 7)
Select 7 to reset the unit’s Channel 1 configuration and expert settings to the default settings. The server configuration settings for IP address, gateway IP address, and netmask remain unchanged. The configurable pins’ settings also remain unchanged. The specific settings that this option changes are listed below:
Channel 1 Configuration Defaults
Baudrate | 9600 |
|
|
I/F Mode | 4C (1 stop bit, no parity, 8 bit, |
|
|
Own TCP port number | 10001 |
|
|
Connect Mode | C0 (always accept incoming connection; no active |
| connection startup) |
|
|
Hostlist retry counter | 3 |
|
|
Hostlist retry timeout | 250 (msec) |
|
|
Start character for serial channel 1 | 0x0D (CR) |
|
|
All other parameters | 0 |
|
|
Expert Settings Defaults
TCP Keepalive time in s | 45 |
|
|
ARP Cache timeout in s | 600 |
|
|
Disable Monitor Mode @ bootup | No |
|
|
HTTP Port Number | 80 |
| |
|
|
MTU Size (512 – 1400) | 1400 |
|
|
Enable alternate MAC | No ( for OEM use only) |
|
|
Ethernet Connection Type | 0 |
|
|
Security Settings Defaults
Disable SNMP | No |
|
|
SNMP community name | public |
|
|
Disable Telnet setup | No |
|
|
Disable TFTP Firmware Update | No |
|
|
Disable Port 77FEh | No |
|
|
Disable Web Server | No |
|
|
UDS1100 User Guide | 58 |