Lantronix UDS1100 manual Entering Monitor Mode Using the Serial Port, Monitor Mode Commands

Page 63

10: Monitor Mode

Monitor Mode is a command-line interface used for diagnostic purposes.

There are two ways to enter Monitor Mode: locally using the serial port or remotely using the network.

Entering Monitor Mode Using the Serial Port

To enter Monitor Mode locally:

1.Follow the same steps used for setting the serial configuration parameters (see Serial Port on page 36).

2.Instead of typing three x keys, however:

a)Type zzz (or xx1) to enter Monitor Mode with network connections.

b)Type yyy (or yy1) to enter Monitor Mode without network connections. A 0> prompt indicates that you have successfully entered Monitor Mode.

Entering Monitor Mode Using the Network Port

To enter Monitor Mode using a Telnet connection:

1.Establish a Telnet session to the configuration port (9999). The following message appears:

2.Type M (upper case) immediately.

A 0> prompt indicates that you have successfully entered Monitor Mode.

Monitor Mode Commands

The following commands are available in Monitor Mode. Many commands have an IP address as an optional parameter (xxx.xxx.xxx.xxx). If you enter the IP address, the command is applied to another unit with that IP address. If you do not enter the IP address, the command is executed locally.

Note: All commands must be in capital letters. Responses to some of the commands are in Intel Hex format.

UDS1100 User Guide

63

Image 63
Contents UDS1100 User Guide Date Rev Comments 900-417 Copyright & TrademarkContacts RevisionsContents Setup Mode Server Configuration Troubleshooting and Contact Information Tables ContentsUsing This Guide Purpose and AudienceChapter Summary Additional Documentation Using This GuideIntroduction ApplicationsApplication Examples Introduction Additional Features Configuration MethodsProtocol Support Sample Hardware Address Product Information LabelGetting Started Package ContentsTo install the unit Installing the UDSIP Address Subnet Mask Gateway Required InformationHardware Address IP AddressSelect Assign a specific IP address and click Next Assigning the IP Address DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressAdding the Unit to the Manage List Accessing the UDS1100 Using DeviceInstallerViewing the Current Configuration To view the units current settingsIP Address on Next Step Assigning the IP Address Serial Port LoginGetting Started Accessing UDS1100 Using DeviceInstaller Configuration Using Web-ManagerLantronix Web-Manager Network ConfigurationStatic IP Address Configuration Automatic IP Address ConfigurationServer Configuration Ethernet ConfigurationTo specify how data will be transmitted To configure the UDS1100’s device server settings Server ConfigurationAdvanced Host List Configuration To configure the host listRetry Settings Host Information Channel 1 ConfigurationSerial Settings To configure the channel’s serial settingsPort Settings ChannelPack Control Flush Output Buffer Network to Serial Connection Settings TCPTo configure a channel’s TCP settings Flush Input Buffer Serial to NetworkConnect Protocol Connect Mode Passive ConnectionConnect Mode Active Connection Endpoint ConfigurationCommon Options Connection Settings UDP Disconnect ModeTo configure a channel’s UDP settings UDP Connection Settings Datagram ModeApply Factory Defaults Apply SettingsTo establish a Telnet connection Configuration via Telnet or Serial Port Setup ModeAccessing Setup Mode Telnet ConnectionExiting Setup Mode To exit setup modeSerial Port Connection Set Gateway IP Address Setup Mode Server ConfigurationServer Configuration Option IP AddressNetwork Class Host Bits Netmask Change Telnet Configuration PasswordNetmask Number of Bits for Host Part Dhcp NameSetup Mode Server Configuration Setup Mode Channel Configuration Channel 1 OptionBaudrate Flow Interface ModeMode Option Common I/F Mode Setting BinaryPort Numbers Reserved for Connect ModePort Number Flow Control Option HexIncoming Connection Connect Mode OptionActive Startup ResponseManual Connection Address Example Modem Mode To enable the hostlistDatagram Type No Carrier MessageMeaningATD Modem Mode Function CommandRemote Port Send the Escape Sequence +++ in Modem ModeAuto Increment Source Port Remote IP AddressDisconnect Mode Option Flush Mode Buffer FlushingOption Pack ControlTrailing Characters DisConnTime Inactivity TimeoutSend Characters Packing IntervalTelnet Terminal Type Channel Port PasswordSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds Http Port Number ARP Cache timeout in secondsDisable Monitor Mode at bootup Enable alternate MACSnmp Community Name Security Settings OptionDisable Snmp Disable Telnet SetupDisable Web Setup Disable Tftp Firmware UpdateDisable Port 77FE Hex Disable Web ServerSecurity Settings Defaults Default Settings OptionChannel 1 Configuration Defaults Expert Settings DefaultsSetup Mode Advanced Settings ROM File Firmware UpgradesUsing Tftp Graphical User Interface Obtaining Firmware Reloading FirmwareTo recover firmware Using Tftp Command Line InterfaceFirmware Upgrades Monitor Mode Commands Monitor ModeEntering Monitor Mode Using the Serial Port Entering Monitor Mode Using the Network PortResponse Meaning Command Command Name FunctionLEDs Troubleshooting and Contact InformationProblem/Message Reason Solution Problems and Error MessagesLock on Technical Support Europe, Middle East, and Africa Technical SupportSerial Connector Pinouts Connections and PinoutsSerial Port Modem Cable DB25 Female Interface RS422 4 wire modeNull Modem Cable Lantronix Part No Network PortPower Plug Ethernet Connector PinoutsCategory Description Technical SpecificationsTechnical Specifications AutoIP Alternative Ways to Assign an IP AddressTo assign a temporary IP address ARP and TelnetConverting Binary to Hexadecimal Conversion TableDecimal Binary Hex Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index UDS1100 User Guide