Falcon SG6K-2TC, SG5K-1TXC True Regenerative On-Line Design, Input Power Factor Correction

Page 5

CHAPTER 1

SG Series UPS - Overview

True Regenerative On-Line Design

As new and innovative technologies have become the backbone of today's businesses, maxi- mum system availability is critical and downtime is more expensive than ever. Increasingly, busi- nesses need a UPS that not only protects against blackouts, but also virtually eliminates more frequent and subtle power disturbances. Surges, sags, line noise and brownouts can disrupt proper operation of sensitive equipment. These disturbances may also create unnecessary pro- duction, service, and data recovery costs.

A True Regenerative On-Line UPS provides the highest level of protection against the widest spectrum of power problems. The incoming AC utility source is converted to a regulated DC voltage. From this DC voltage, a new AC voltage is regenerated, providing continuous, clean, tightly regulated power to your equipment. Line-interactive and Off-line designs leave your equip- ment connected directly to dirty utility power. They only provide minimal transient, voltage and backup protection. If your equipment operation is "Mission Critical", a true double conversion On-Line UPS, such as Falcon® Electric's SG SeriesTM UPS Plus®, is the only clear choice.

Input Power Factor Correction

All SG Series UPS Plus models include state-of-the-art Input Power Factor Correction. This greatly reduces the amount of current demanded from your building wiring system, yielding a highly efficient, "building friendly" UPS.

Microprocessor Control

Falcon Electric's SG Series UPS incorporates advanced microprocessor technology. This tech- nology makes possible a high level of internal UPS control and management. With the supplied UPSILON® software, all SG Series UPS models support unattended shutdown, management, data logging, and self-diagnostics. The software supports MS Windows® 95, 98, NT, 2000, 2000 Server, ME, XP, Novell Netware® 5 & 6, LINUX and FreeBSD. UPSILON for UNIX may be purchased seperately and supports most popular UNIX platforms and OS versions.

SNMP/HTTP Remote Management Support

Our SNMP/HTTP Agent board provides remote management and monitoring over any Ethernet LAN, WAN or the Internet utilizing a 10BaseT-type connection. The optional SNMP/HTTP agent installs via an option slot located behind a cover plate on the back panel of every SG Series model.

Extended Battery Bank Option

All SG Series models have a continuous duty inverter and support the addition of optional exter- nal battery/charger packs. Whether your application requires a few additional minutes or hours, the SG Series will be ready. Falcon also offers optional battery charger upgrades for faster recharging. Please specify your extended battery and charger requirements at the time of your initial order.

Frequency Converter Option

With a factory modification at the time of order, any SG Series model can be configured for use as an international frequency converter. This makes the SG Series UPS Plus an ideal choice for worldwide power applications. Without this modification, all SG series models will detect the incoming utility line frequency and automatically set its output frequency to match.

3

Image 5
Contents Owners Operating Manual Table of Contents SG Series ON-LINE UPS System Block Diagram Electric, Inc Important Safety InstructionsExtended Battery Bank Option Input Power Factor CorrectionTrue Regenerative On-Line Design Microprocessor ControlGeneral Common for all models Installation InstructionsDisregard On Designation Leveling Feet Adjustment Model UPS Output Requirements View of the Input/Output Hardwire Terminal BlockOutput Requirements Do not USE the Upper Terminal ConnectionsSG5K-2TC & SG6K-2TC Internal UPS DiagramSG5K-2TXC & SG6K-2TXC Installation InstructionsExtended Battery Bank Selection Guide USE Copper Conductors only UPS Output Details Model RequiredReceptacle Typical Power Distribution Center Configuration Output Power Distribution CenterRefer to page 20 for Operating Instructions Installation Procedure Extended Battery Bank DC InterconnectionAll models except hardwire Battery Level Indicator LEDs Load Level Indicator LEDsLine / Site Wiring Fault Indicator LED Battery Mode Indicator LEDInverter Indicator LED Bypass Indicator LEDGreen Mode LED Indicator Over Crest Indicator LEDCategory two alarms Audible AlarmsCategory one alarms Page Supported Protocols Communications InterfacesLocation DRY Contact & Opto Coupler Interface Board Options PIN Assignment for the Falcon Battery Replacement Care & MaintenanceBattery Life vs. Temperature FCC Considerations Storing the UPS and BatteriesRequesting Technical Information or Support Technical SupportSUPPORT@FALCONUPS.COM 800.842.6940 Falcon Web SupportGeneral Provisions Warranty6kVA Models