APPENDIX A

 

&Q5, &Q6

Asynchronous escape.

 

&Q2, &Q3

The modem hangs up.

&D2

Interpret DTR ON-to-OFF transition per &Qn:

 

&Q0 thru &Q6

The modem hangs up.

&D3

Interpret DTR ON-to-OFF transition per &Qn:.

 

&Q0, &Q1, &Q4,.

 

 

&Q5, &Q6

The modem performs soft reset.

 

&Q2, &Q3

The modem hangs up.

&F0

Restore factory configuration 0.

&F1

Restore factory configuration1.

&G0

Disable guard tone.

 

&G1

Disable guard tone.

 

&G2

Enable 1800 Hz guard tone.

&J0

Set S-Register response only for compatibility.

&J1

Set S-Register response only for compatibility.

&K0

Disable DTE/DCE flow control.

&K3

Enable RTS/CTS DTE/DCE flow control.

&K4

Enable XON/XOFF DTE/DCE flow control.

&K5

Enable transparent XON/XOFF flow control.

&K6

Enable both RTS/CTS and XON/XOFF flow control.

&L0

Select dial up line operation.

&L1

Select leased line operation.

&M0

Select direct asynchronous mode.

&M1

Select sync connect with async off-line command mode.*

&M2

Select sync connect with async off-line command mode and enable DTR dialing of directory zero.*

&M3

Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.*

&P0

Set 10 pps pulse dial with 39%/61% make/break.

&P1

Set 10 pps pulse dial with 33%/67% make/break.

&P2

Set 20 pps pulse dial with 39%/61% make/break.

&P3

Set 20 pps pulse dial with 33%/67% make/break.

&Q0

Select direct asynchronous mode.

&Q1

Select sync connect with async off-line command mode.*

&Q2

Select sync connect with async off-line command mode and enable DTR dialing of directory zero.*

&Q3

Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.*

&Q4

Select Hayes AutoSync mode.

- 24 -

Image 28
Contents ThinCom Pcmcia Ethernet Modem Adapter User=s Manual Copyright Table of Contents Register Summary Introduction System RequirementIntroduction Installation Hardware Installation GuideInstallation Installation Verification Network Environment Driver selectionInstallation Installation Testing the Modem Testing the NetworkInstall the Thincom Card Windows 95 InstallationIf Something Goes Wrong Enabling 32-BIT Card Support in Windows Installation Verification ModemNetwork Installation Data Communication Operation Operating Mode Operating ModeRemote Access Data CommunicationFile Transferring Cellular OperationFAX Operation FAX OperationPage Diagnostic Diagnostic FunctionTroubleshooting TroubleshootingNo Dial Tone Appendix a CS.EXE Pcmcs Ctalkcs Basic AT= command for 28,800 Modem Command Function Appendix a Set 10 pps pulse dial with 39%/61% make/break Modem negotiates an error corrected link MNP 10 Commands ECC ComandsEnable MNP 10 extended services detection only Caller ID CommandsCellular Commands Basic AT= command for 1414 CL Command Default FunctionIs enabled when DTR is turned on Configured. DTR optionHz guard tone enabled Disabled QAM modulation onlyATDS=n command = 0, 9, A, B, C, D, #, *, T, P, R, W, @ 42, MNP AT Commands Default FunctionS37000 S90000 S108002 S109062 Range No RetrainEnable Bps rate adjusting Disables V.42 bis Enables V.42 bis only when transmitting dataEnables V.42 bis only when receiving data Dial Modifiers Command FunctionCommand Function Return the value of default S register ECC Commands Operating Consideration Register Summary Function Range Units Function Range UnitsFunction Range S33 Xoff Character 255 Appendix B Page FCC Compliance Statements FCC PartFCC Consumer Information and FCC Requirements Canadian Department of Communications compliance statements Page