EXP Computer PCMCIA Ethernet Modem Adapter user manual Return the value of default S register

Page 39

APPENDIX A

?

Return the value of default S register.

T

Force DTMF dialing.

V0

Report short form (terse) result codes.

V1

Report long form (verbose) result codes.

W0

Report DTE speed in EC mode.

W1

Report line speed, EC protocol and DTE speed.

W2

Report DCE speed in EC mode.

X0

Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER and ERROR.

X1

Report basic call progress result codes and connections speeds (OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER,

 

CONNECT XXXX, and ERROR.

X2

Report basic call progress result codes and connections speeds, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO

 

ANSWER, CONNECT XXXX, and ERROR.

X3

Report basic call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, and ERROR.

X4

Report all call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR.

Y0

Disable long space disconnect before on-hook.

Y1

Enable long space disconnect before on-hook.

Z0

Restore stored profile 0 after warm reset.

Z1

Restore stored profile 1 after warm reset.

&C0

Force RLSD active regardless of the carrier state.

&C1

Allow RLSD to follow the carrier state.

&D0

Interpret DTR ON-to-OFF transition per &Qn.

&D1

Interpret DTR ON-to-OFF transition per &Qn.

&D2

Interpret DTR ON-to-OFF transition per &Qn.

&D3

Interpret DTR ON-to-OFF transition per &Qn.

&F

Recall (restore) factory profile.

&G0

Disable guard tone.

&G1

Disable guard tone.

&G2

Enable 1800 Hz guard tone.

&J0

Set S register response only for compatibility.

&J1

Set S register response only for compatibility.

&K0

Disable DTE/DCE flow control.

&K3

Enable RTS/CTS DTE/DCE flow control.

&K4

Enable XON/XOFF DTE/DCE flow control.

&L0

Select dial up line operation.

&L1

Select leased line operation.

&M0

Select direct asynchronous mode.

&M1

Select sync connect with async off-line command mode.

&M2

Select sync connect with async off-line command mode and enable DTR dialing of directory zero.

&M3

Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.

&P0

Set 10 pps pulse dial with 39%/61% make/break.

&P1

Set 10 pps pulse dial with 33%/67% make/break.

&P2

Set 20 pps pulse dial with 39%/61% make/break.

&P3

Set 20 pps pulse dial with 33%/67% make/break.

&Q0

Select direct asynchronous mode.

&Q1

Select sync connect with async off-line command mode.

&Q2

Select sync connect with async off-line command mode and enable DTR dialing of directory zero.

&Q3

Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.

&Q4

Select Hayes AutoSync mode.

&Q5

Modem negotiates an error corrected link.

&Q6

Select asynchronous operation in normal mode.

- 35 -

Image 39
Contents ThinCom Pcmcia Ethernet Modem Adapter User=s Manual Copyright Table of Contents Register Summary System Requirement IntroductionIntroduction Hardware Installation Guide InstallationInstallation Network Environment Driver selection Installation VerificationInstallation Testing the Network Installation Testing the ModemWindows 95 Installation Install the Thincom CardIf Something Goes Wrong Enabling 32-BIT Card Support in Windows Modem Installation VerificationNetwork Installation Data Communication Operation Operating Mode Operating ModeCellular Operation Remote AccessData Communication File TransferringFAX Operation FAX OperationPage Diagnostic Function DiagnosticTroubleshooting TroubleshootingNo Dial Tone Appendix a CS.EXE Pcmcs Ctalkcs Basic AT= command for 28,800 Modem Command Function Appendix a Set 10 pps pulse dial with 39%/61% make/break Modem negotiates an error corrected link ECC Comands MNP 10 CommandsCaller ID Commands Enable MNP 10 extended services detection onlyCellular Commands Command Default Function Basic AT= command for 1414 CLDisabled QAM modulation only Is enabled when DTR is turned onConfigured. DTR option Hz guard tone enabledRange No Retrain ATDS=n command = 0, 9, A, B, C, D, #, *, T, P, R, W, @42, MNP AT Commands Default Function S37000 S90000 S108002 S109062Enable Bps rate adjusting Dial Modifiers Command Function Disables V.42 bisEnables V.42 bis only when transmitting data Enables V.42 bis only when receiving dataCommand Function Return the value of default S register ECC Commands Operating Consideration Function Range Units Register Summary Function Range UnitsFunction Range S33 Xoff Character 255 Appendix B Page FCC Part FCC Compliance StatementsFCC Consumer Information and FCC Requirements Canadian Department of Communications compliance statements Page