4 OPERATION

This section discusses the general PDI operation (Section 4.1), user-programmable features (Section 4.2), data commands (Section 4.3), event sample reporting (Section 4.4), and presentation (Section 4.5).

4.1GENERAL

The V79 PDI-1 and V80 PDI-2 modules are used in applications requiring notification of device status (e.g., burglar and fire alarms, event counters/timers, process control, etc.). The PDI-1 module has 16 channel switch inputs providing a reliable method to detect and report a state change from high resistance (open) to continuity (closed) or vice versa. The V80 is a 16 channel optically-isolated voltage input module that is non-polarity sensitive and can be individually set to detect the presence or the change of state of AC or DC inputs. We will refer to a change in state of a switch closure (PDI-1) or a voltage change (PDI-2) as an event. An event sample is the actual data associated with an event which is calculated by the PDI module and sent to the host computer/controller.

Individual PDI channels can be programmed to report event samples upon request via data commands (Command Reporting Method), at a specific date/time (Schedule Reporting Method), or as the event occurs (Immediate Reporting Method). Multiple events may be stored for later retrieval and analysis. The PDI features a latch mode where the time and state of the initial event is latched and held until user reset. False reporting of events is prevented by programming variable debounce times. Event samples are preceded by the appropriate unit, module, and channel number and may be appended with a "real time" Time Tag showing the date and time the status was recorded.

You have the choice of programming the PDI via verbose (menu-driven) or non- verbose (dynamic) configuration mode. When using verbose mode, a series of menus will prompt you to enter the desired parameters. Non-verbose mode allows you to program the PDI by downloading configuration commands (see Section 5.2).

7

Image 11
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Reporting Method USER-PROGRAMMABLE FeaturesSampling Setup Reporting SetupHost Address Report Start TimeReport Interval Terminating Characters Dynamic ConfigurationData Commands Take a single sample for Ports Clear Event Latch Data Clear Event Buffer CommandClear Event Counter Command Report Event Duration Command Report ALL Buffered Events CommandReport Event Counter Command Report Event Latch Data and Reset Command Report Event Latch Data CommandReport Event Counter and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Time TAG Command Debounce Delay CommandReporting Method Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page