5.1.4.4 HOST ADDRESS

By responding to the Enter Selection: message at the end of the Reporting Setup Menu on page 23 with "4" (Host Address), you may program the address of the designated host module. The designated host module is where event samples are sent when using Immediate or Schedule Reporting Method. The PDI will respond with the Host Address menu as follows:

HOST ADDRESS

Host Address

1:1,1

Enter Unit Number (1-32) <cr>, or X to EXIT:

Enter Module Number (1-16) <cr>, or X to EXIT:

Enter Port Number (1-4) <cr>, or X to EXIT:

Enter the appropriate Host Address. This consists of the Unit Number (1 to 32), Module Number (1 to 16), and Port Number (1 to 4) where the designated host module is located. Each entry should be followed by <ENTER>. If there is a single M Series unit in service, the Host Address would typically be Unit 1, Module 1, Port 1.

NOTE: The Host Address must be supplied to direct self-reporting event samples to the desired destination. If the Host Address is incorrect, self-reporting event samples will be misdirected or lost.

5.1.4.5 TIME TAG

By responding to the Enter Selection: message at the end of the Reporting Setup Menu on page 23 with "6" (Time Tag), you may program the PDI to append a time tag to the end of event samples automatically. The PDI will respond with the Enable/Disable Time Tagging menu as follows:

ENABLE / DISABLE TIME TAGGING

Time Tagging

DISABLED

Enable

1

Disable

2

Exit

X

Enter Selection:

 

27

Image 31
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Reporting Method USER-PROGRAMMABLE FeaturesSampling Setup Reporting SetupReport Interval Report Start TimeHost Address Data Commands Dynamic ConfigurationTerminating Characters Take a single sample for Ports Clear Event Counter Command Clear Event Buffer CommandClear Event Latch Data Report Event Counter Command Report ALL Buffered Events CommandReport Event Duration Command Report Event Counter and Reset Command Report Event Latch Data CommandReport Event Latch Data and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Reporting Method Command Debounce Delay CommandTime TAG Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page