Bay Technical Associates V80 PDI-2, V79 PDI-1 Dynamic Configuration Procedure and Commands

Page 34

5.2DYNAMIC CONFIGURATION PROCEDURE AND COMMANDS

PDI-1 or PDI-2 dynamic configuration commands are issued through a host module. Some configuration commands apply to all types of DAC modules, while others apply to specific modules. The PDI will recognize dynamic configuration commands only when Dynamic Configuration is enabled (see Section 5.1.5). Use the following procedure to send dynamic configuration commands to the PDI from a host module:

1.Select the PDI from the host module by sending a select sequence which consists of the port select code ($BT - default), the appropriate unit number followed by a colon (01: to 30: - only if using cascaded units), the desired module number (2 to 16), and a terminating character of Carriage Return (0D Hex) or Line Feed (0A Hex). For example, to select an PDI Module located in slot 15 of a non-cascaded unit using the default port select code, send $BT15<cr>.

2.Once the PDI is selected, it will go into Command Mode and allow you to send dynamic configuration commands. The PDI configuration commands begin with two capital letters designating the specific command and are terminated with a Carriage Return. Most configuration commands require a number between the command letters and Carriage Return. This number represents the desired configuration parameter.

3.After you have sent the desired configuration command(s) to the PDI module, you may disconnect from the PDI, by sending $BT<cr>. You may disconnect from the PDI and select a different module or the base unit by sending $BTX<cr>, where X is the desired module number or 0 for the base unit.

Section 5.2.1 and Section 5.2.3 provides detailed information on the functionality of each configuration command supported by the PDI. Appendix A provides these commands as a quick reference.

30

Image 34
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Installation CablingPDI-2 AC Input Setup Operation Reporting Setup USER-PROGRAMMABLE FeaturesSampling Setup Reporting MethodReport Interval Report Start TimeHost Address Data Commands Dynamic ConfigurationTerminating Characters Take a single sample for Ports Clear Event Counter Command Clear Event Buffer CommandClear Event Latch Data Report Event Counter Command Report ALL Buffered Events CommandReport Event Duration Command Report Event Counter and Reset Command Report Event Latch Data CommandReport Event Latch Data and Reset Command Report a Single Buffered Event Command Event Sample ReportingPage Event Sample Presentation 115,1 1320 11/18/93 Configuration MENU-DRIVEN ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Reporting Method Command Debounce Delay CommandTime TAG Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page