Configuring OC3-ATM Cards (MAX TNT/DSLTNT)
Overview of OC3-ATM settings
Parameter | Specifies |
Name | Name of the interface. The default value is the interface address in |
| shelf:slot:item format (for example, 1:2:3), but you can assign |
| a text string of up to 16 characters. |
Enabled
Physical address of the
Enable/disable the
Not currently used. Leave the default value (zero). | |
| Connection or RADIUS profile specifies this number to make use |
| of the interface. Each interface must be assigned a number from 1 |
| to 1024 that is unique within the system. |
Loopback
Not currently used. Leave the default value (the zero address).
Enable/disable loopback for diagnosing connectivity or possible equipment problems. Loopback is disabled by default, which is required for normal operations.
Frame format for data transmitted on the interface. Valid settings | |
| are sdh (the default) and sonet, which represent the |
| synchronous digital hierarchy (SDH) and synchronous optical |
| network (SONET) frame formats, respectively. |
Framing operations. Only the default | |
| which represents both the 155.52Mbps interface in the U.S. and |
| the equivalent European 155.52Mbps interface |
Enable/disable descrambling of the entire receive stream. This | |
| function is enabled by default. Disable it by setting this parameter |
| to yes only if the |
| functions. |
Enable/disable scrambling of the entire transmit stream. This | |
| function is enabled by default. Disable it by setting this parameter |
| to yes only if the |
| functions. |
Enable/disable descrambling of the | |
received cells. This function is enabled by default. Disable it by | |
| setting this parameter to yes only if the |
| disabled the corresponding functions. |
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide |