Configuring DSL Connections (DSLTNT)

Sample DSL configurations

Before you configure the Pipeline, make sure of the following:

The PC connected to the Pipeline has an IP address on the same subnet as the Pipeline.

The IP address of the Pipeline is configured as the default gateway for the PC.

To configure the Pipeline:

1From the Main Edit menu, select Configure.

2Specify the following values:

Chan Usage=Leased/Unused

My Name=sdsl-pipeline

My Addr=192.168.216.1/24

Rem Name=max-tnt

Rem Addr=192.168.215.135/24

Route=IP

3Exit and save the Configure profile.

4From the Main Edit menu, select Ethernet > Connections > max-tnt.

5Specify the following values:

Active=Yes

Encaps=FR

Route IP=Yes

6Open the Encaps Options submenu.

7Specify the following values:

FR Prof=Frame Relay

DLCI=16

8Exit the Connection profile and save your changes.

Next, set up the Frame-Relay profile.

1Open the Ethernet > Frame Relay > Frame Relay profile.

2Specify the following values:

Name=Frame Relay

Active=Yes

Call Type=Nailed

3If your Pipeline supports it, set LinkUp to Yes:

LinkUp=Yes

Note that this parameter does not appear in recent versions of Pipeline software.

4Exit the Frame-Relay profile and save your changes.

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide