Signaling System 7 (SS7)
Configuring an SS7 signaling gateway
[in T1/{
Parameter
Usage for SS7 data trunks
For an SS7 data trunk, which carries no signaling, this parameter can be set to either of the following values. The setting registers the line with the signaling gateway and allows the gateway to take control of the line and its calls.
Specifies how the TAOS unit processes incoming calls on this line. For SS7 data trunks, the parameter must be set to
T1 lines typically use channel 24 for signaling. For SS7 data trunks, the
Example of configuring a T3 card for SS7 data
To configure lines of a T3 card as SS7 data trunks, you must first configure the T3 profile as in the following example:
admin> read t3 {1 1 1} T3/{
admin> set enabled = yes
admin> set
admin> set
admin> write
T3/{
After configuring the T3 line, configure the individual T1 lines that constitute the T3 line as explained in the next section.
Example of configuring a T1 data trunk
The following commands configure a T1 line as an SS7 data trunk, enabling the signaling gateway to control the line:
admin> read t1 {1 1 7}
T1/{