Configuring Series56 II and III Modem and Hybrid Access Cards
Series56 II and III Call-Route profiles
rate and the
Following is the relevant parameter, which is shown with its default setting:
[in
The value of this parameter must be valid AT commands, up to 36 characters. Do not begin the string with AT. An AT is appended to the beginning of this string automatically before it is sent to the modem. Also, do not include an A (answer) or a D (dial) command anywhere in the string. An A command is appended automatically to the end of this string, and a D command in the answer string causes the call to fail.
Note: Be very careful when entering AT commands in this parameter. The system does not prevent you from entering incorrect strings.
The following example sets the
ATS37=11A
When the modem receives this string, it forces a V.32bis 14400 connection.
admin> read
admin> set modem
admin> write
Series56 II and III Call-Route profiles
When you install a Series56 II or Series56 III slot card, the TAOS unit creates two call route profiles for each channel on the card. One for a digital data call and one for a modem voice call. For example:
admin >callroute -d
device | # | source | type | tg | sa phone |
1:14:01/0 | 0 | 0:00:00/0 | 0 | 0 | |
1:14:01/0 | 1 | 0:00:00/0 | 0 | 0 | |
1:14:02/0 | 0 | 0:00:00/0 | 0 | 0 | |
1:14:02/0 | 1 | 0:00:00/0 | 0 | 0 | |
1:14:03/0 | 0 | 0:00:00/0 | 0 | 0 | |
1:14:03/0 | 1 | 0:00:00/0 | 0 | 0 | |
1:14:04/0 | 0 | 0:00:00/0 | 0 | 0 | |
1:14:04/0 | 1 | 0:00:00/0 | 0 | 0 | |
1:14:05/0 | 0 | 0:00:00/0 | 0 | 0 | |
1:14:05/0 | 1 | 0:00:00/0 | 0 | 0 |
Note that in
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide |