Configuring OC3-ATM Cards (MAX TNT/DSLTNT)

Example of an OC3-ATM configuration

For example, the following commands configure an OC3-ATM port as an eligible clock source. If this port becomes unavailable and is not backed up, the unit begins using the built-in clock on the shelf controller.

admin> read oc3-atm { 1 7 1 } OC3-ATM/{ shelf-1 slot-7 1 } read

admin> set line-config clock-source = eligible

admin> set line-config clock-priority = high

admin> write

OC3-ATM/{ shelf-1 slot-7 1 } written

Example of an OC3-ATM configuration

In this example, the administrator enables an OC3-ATM interface in slot 7, assigns the nailed group number 222 to the interface, and sets the VPI-VCI range to allow an 8-bit VPI number:

admin> read oc3-atm {1 7 1} OC3-ATM/{ shelf-1 slot-7 1 } read

admin> set enabled = yes

admin> set line-config nailed-group = 222

admin> set line-config vpi-vci-range = 0-255/32-255

admin> write

OC3-ATM/{ shelf-1 slot-7 1 } writtens

Note: For details about configuring ATM features and connections, see the APX 8000/MAX TNT/DSLTNT ATM Configuration Guide.

15-4

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

Page 148
Image 148
Lucent Technologies 7820-0802-003 manual Example of an OC3-ATM configuration