Configuring DSL Connections (DSLTNT)

Configuring IDSL voice connections

techpubs-lab-25> list line-interfacechannel-config[in T1/{ shelf-1 slot-1 1 }:line-interface:channel-config]

channel-config[1] = { switched-channel 9 "" { any-shelf any-slot + channel-config[2] = { switched-channel 9 "" { any-shelf any-slot + channel-config[3] = { switched-channel 9 "" { any-shelf any-slot + channel-config[4] = { switched-channel 9 "" { any-shelf any-slot + channel-config[5] = { switched-channel 9 "" { any-shelf any-slot +

..

..

6Assign each T1 channel to a trunk group. For example:

admin> set 1 trunk = 5 admin> set 2 trunk = 5 admin> set 3 trunk = 5 admin> set 4 trunk = 5 admin> set 5 trunk = 5 admin> set 6 trunk = 5 admin> set 7 trunk = 5 admin> set 8 trunk = 5 admin> set 9 trunk = 5 admin> set 10 trunk = 5

..

..

This trunk group number must be prepended to the number dialed by users dialing out from the Pipeline.

7Write the T1 profile:

admin> write

T1/{ shelf-1 slot-1 1 } written

Configuring the Pipeline

When configuring a remote ISDN device to attach to the IDSL line card, always select ATT 5ESS Point-to-Point as the switch type. The IDSL line card can only emulate the ATT 5ESS Point-to-Point switch. (If you are connecting using a Pipeline, you can specify an IDSL switch type. This selection emulates an ATT 5ESS Point-to-Point switch with en-bloc dialing support, which is required for IDSL voice calls.)

Before you configure the Pipeline, make sure the PC connected to the Pipeline has an IP address on the same subnet as the Pipeline, and that the IP address of the Pipeline is configured as the default gateway for the PC.

Configuring the Configure profile

The Pipeline Configure profile allows you to set up the basic parameters for a connection. To configure the Pipeline Configure profile:

1From the Main Edit menu, select Configure.

2Specify the following values:

Switch Type=IDSL

Chan Usage=Switch/Switch

My Num A=55105554444

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

17-21

Page 173
Image 173
Lucent Technologies 7820-0802-003 manual Configuring the Pipeline, Configuring the Configure profile