Configuring T1 Cards

Configuring NFAS

admin> read t1 {1 2 1}

T1/{ shelf-1 slot-2 1 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 0

admin> set line nfas-group-id = 1

admin> set channel 24 channel = nfas-primary admin> write

T1/{ shelf-1 slot-2 1 } written

admin> read t1 {1 2 2}

T1/{ shelf-1 slot-2 2 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 1

admin> set line nfas-group-id = 1

admin> set line channel 24 channel = nfas-secondary admin> write

T1/{ shelf-1 slot-2 2 } written

admin> read t1 {1 2 3}

T1/{ shelf-1 slot-2 3 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 2

admin> set line nfas-group-id = 1 admin> write

T1/{ shelf-1 slot-2 3 } written

admin> read t1 {1 2 4}

T1/{ shelf-1 slot-2 4 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 3

admin> set line nfas-group-id = 1 admin> write

T1/{ shelf-1 slot-2 4 } written

The following commands configure NFAS group 2, which contains lines 5 through 8:

admin> read t1 {1 2 5}

T1/{ shelf-1 slot-2 5 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 0

admin> set line nfas-group-id = 2

admin> set channel 24 channel = nfas-primary admin> write

T1/{ shelf-1 slot-2 5 } written

admin> read t1 {1 2 6}

T1/{ shelf-1 slot-2 6 } read

admin> set line signaling-mode = isdn-nfas admin> set line nfas-id = 1

admin> set line nfas-group-id = 2

admin> set line channel 24 channel = nfas-secondary

7-14

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

Page 86
Image 86
Lucent Technologies 7820-0802-003 manual T1/ shelf-1 slot-2 2 read