Configuring T3 Cards

Understanding T3 configuration requirements

For complete information about the associated parameters, see the APX 8000/MAX

TNT/DSLTNT Reference.

Table 11-1. T3 line configuration tasks

Section

Description of task

Associated parameters

 

 

 

“Understanding T3 configuration

Although you configure the T3 card similarly

Clock-Source

requirements” on page 11-2

to the eight-port T1 card, there are important

Clock-Priority

 

differences you must understand before

 

NFAS-ID

 

configuring the card.

 

 

FDL

 

 

Front-End-Type

 

 

DSX-Line-Length

 

 

CSU-Buildout

 

 

 

“Understanding T3 slot card

The TAOS unit creates a single T3 profile

N/A

profiles” on page 11-3

and 28 T1 profiles for each T3 card in the

 

 

system.

 

 

 

 

“Assigning a name to a T3 profile”

Assign a name to the T3 profile.

Name

on page 11-4

 

 

 

 

 

“Enabling a line” on page 11-5

Make a line available for use.

Enabled

 

 

 

“Configuring the T3 physical link”

Before you configure the T1 profiles that

Physical-Address

on page 11-5

make up the T3 card, you must first configure

Enabled

 

the T3 physical line parameters in the T3

 

Frame-Type

 

profile.

 

 

Line-Length

 

 

 

“Configuring clocking” on

Any of the T1 lines associated with a T3 card

Clock-Source

page 11-5

can be configured as the clock source for the

Clock-Priority

 

TAOS unit.

 

 

 

 

 

Understanding T3 configuration requirements

Configuring the T3 slot card is very similar to configuring the eight-port T1 slot card, but with some important differences. Table 11-2lists the differences.

Table 11-2. Differences between T3 card configuration and T1 card configuration

Parameter

Difference

 

 

NFAS-ID

The T3 card supports up to 14 NFAS groups. An NFAS

 

group can be composed of up to 28 lines, subject to the

 

limitations of the switch. NFAS is configured in the

 

same way as for the eight-port T1 card.

 

 

11-2

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

Page 126
Image 126
Lucent Technologies 7820-0802-003 manual Understanding T3 configuration requirements, Parameter Difference