Configuring DSL Connections (DSLTNT)

Sample DSL configurations

Configuring the SDSL profile

To configure the SDSL profile:

1Read in the SDSL profile. For example, if the SDSL card is installed in slot 11 of shelf 1 and the remote DSLPipe-S is connected to port 1:

admin> read sdsl {1 11 1}

2Enable the port:

admin> set enabled=yes

3List the contents of the Line-Config profile: admin> list line-config

[in SDSL/{ shelf-1 slot-11 1 }:line-config] trunk-group = 0

nailed-group = 1 activation = static

call-route-info = { any-shelf any-slot 0 } max-rate = 144000

unit-type = coe

4Assign this port to a nailed group: admin> set nailed-group=1

This nailed group points to the Frame-Relay profile you will create later. The nailed group must be unique for each active WAN interface.

5Write the profile: admin> write

Configuring the Frame-Relay profile

See the APX 8000/MAX TNT/DSLTNT Frame Relay Configuration Guide for more information and examples.

To configure the Frame-Relay profile:

1Create a new Frame-Relay profile: admin> new frame-relayfr-prof-1

2Enable the profile:

admin> set active=yes

3Assign the Frame-Relay profile to a nailed-up group: admin> set nailed-up-group=1

This value must be the same as the SDSL nailed group number you configured in the SDSL profile. The nailed group must be unique for each active WAN interface.

4Write the profile: admin> write

17-32

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

Page 184
Image 184