Signaling System 7 (SS7)

Cause codes for SS7 ASGCP calls to the TAOS unit

ft1-caller = 0

calling-number = { "" unknown unknown unspecified unspecified } force-56kbps = 0

redirect-number = "" call-direction = 0

global-call-id = 03040506-0102-0900-0807-010203040506

Start and Stop records

The Ascend_Global_Call_Id attribute in the Start and Stop records for SS7 VoIP and data calls is for call-logging only, not RADIUS, and is reported only when the global call ID is available.

The TAOS unit sends Stop records for SS7 calls that are cleared or rejected at the SS7 IPDC layer. Those calls do not have Start records, because they are never routed to host cards.

Disconnect cause codes

The following set of disconnect cause codes reports the cause of termination for calls that are cleared or rejected at the SS7 IPDC layer. These codes are based on the cause codes defined by ITU-T Recommendation Q.850, Usage of Cause and Location in the Digital Subscriber Signaling System No. 1 and the Signaling System No. 7 ISDN User Part. This group of cause codes begins at offset 800.

Event

DIS_Q850_UNASSIGNED_NUMBER DIS_Q850_NO_ROUTE DIS_Q850_NO_ROUTE_TO_DEST DIS_Q850_CHANNEL_UNACCEPTABLE DIS_Q850_NORMAL_CLEARING DIS_Q850_USER_BUSY DIS_Q850_NO_USER_RESPONDING DIS_Q850_USER_ALERT_NO_ANSWER DIS_Q850_CALL_REJECTED DIS_Q850_NUMBER_CHANGED DIS_Q850_DEST_OUT_OF_ORDER DIS_Q850_INVALID_NUMBER_FORMAT

DIS_Q850_FACILITY_REJECTED DIS_Q850_RESP_TO_STAT_ENQ DIS_Q850_UNSPECIFIED_CAUSE DIS_Q850_NO_CIRCUIT_AVAILABLE DIS_Q850_NETWORK_OUT_OF_ORDER

Code

Q.850 Definition

801Unallocated (unassigned) number

802No route to specified transit network

803No route to destination

806Channel unacceptable

816Normal call clearing

817User busy

818No user responding

819No answer from user (user alerted)

821Call rejected

822Number changed

827Destination out of order

828Invalid number format (address incomplete)

829Facility rejected

830Response to STATUS ENQUIRY

831Unspecified normal event

834No circuit or channel available

838Network out of order