Configuring DSL Connections (DSLTNT)

Sample DSL configurations

Figure 17-5. Example SDSL setup with interface-based routing

192.168.216.1/24

SDSL port address

DSLPipe address

192.168.23.142/30

192.168.23.141/30

local loop (SDSL)

COE (MAX TNT)

CPE (DSLPipe-S)

LAN Adrs= 192.168.23.141/30

WAN Alias=0.0.0.0

IF Adrs=192.168.23.142/30

Configuring an SDSL connection requires the following general steps:

Configuring the Connection profile

Configuring an IP-Route profile

Configuring the SDSL profile

Configuring the Frame-Relay profile

Configuring the DSLPipe-S

Configuring the Connection profile

To configure the Connection profile:

1Create a new Connection profile:

admin> new connection sdsl-pipeline

2Enable the profile:

admin> set active=yes

3Specify the encapsulation type as Frame Relay:

admin> set encapsulation-protocol=frame-relay

4List the IP-Options submenu: admin> list ip-options

[in CONNECTION/sdsl-pipeline:ip-options] ip-routing-enabled = yes vj-header-prediction = yes remote-address = 0.0.0.0/0 local-address = 0.0.0.0/0

..

..

5Set the IP address of the DSLPipe-S connecting to the DSLTNT: admin> set remote-address=192.168.23.141/30

6Set the IP address of the DSLTNT SDSL port:

17-30

APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide

Page 182
Image 182