Configuring the Thermal Profile for Fan Tray Operations (APX 8000)
Thermal status reporting
Thermalstatus command
The thermalstatus command displays a number of
•Ambient temperature at fan tray intake.
•Shelf controller temperature.
•High, Low, and Alarm temperature thresholds.
•Slot card temperature for slot cards that support temperature reporting. Currently, no slot cards support thermal information reporting.
•Power supply thermal status, and whether the power supplies are in an overheated state.
•Fan tray status, including the fan tray operational mode, number of revolutions per minute at
For example:
admin> thermalstatus
System | Thermal status |
|
|
|
|
|
|
Ambient temperature at intake | : 27 | C (80 | F) | ||||
Shelf | controller temperature |
| : 35 | C (95 | F) | ||
High temperature threshold | : | 36 | C | (96 | F) |
| |
Low temperature threshold | : | 32 | C | (89 | F) |
| |
Alarm | temperature threshold : | 38 | C | (100 F) |
Slot cards:
(no slot cards contain thermal information)
Power supply thermal status
Power Supply # | Temp |
================================= | |
A | OK |
B | OK |
C | n/a |
D | OK |
Fantray status |
|
|
Fan operational mode: | ||
| 2000 | |
Current fan mode: | ||
Fan # | RPM | Status |
============================================
1 | 3289 | GOOD |
2 | 3214 | GOOD |
3 | 3075 | GOOD |
4 | 3143 | GOOD |
5 | 3214 | GOOD |
6 | 3289 | GOOD |
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide |