Lucent Technologies 7820-0802-003 manual Configuring a MultiDSP card

Models: 7820-0802-003

1 242
Download 242 pages 8.02 Kb
Page 66
Image 66

Configuring MultiDSP Cards (MAX TNT, APX 8000)

Configuring a MultiDSP card

For example, enter the following command to display information about a 96-port MultiDSP card (identified as madd2-card) installed in shelf 1, slot 10 of a MAX TNT unit:

admin> show 1 10

 

 

 

 

{ shelf-1 slot-10

0

}

UP

madd2-card:

{ shelf-1 slot-10

1

}

UP

madd-modem-1

{ shelf-1

slot-10

2

}

UP

madd-modem-2

{ shelf-1

slot-10

3

}

UP

madd-modem-3

...

 

 

 

 

 

{ shelf-1

slot-10

96 }

UP

madd-modem-96

Verifying that installed software and software versions are correct

The dircode command displays descriptions and version numbers of all software currently installed on the unit’s flash memory card.

Use the dircode command to verify that the software version numbers for the system (shelf controller) and MultiDSP card (shown as madd-card) are correct.

The following example shows the installed software versions for a MAX TNT system (shelf controller) and 48-port MultiDSP card:

admin> dircode

Flash card code directory:

Card 1, directory size 16

shelf-controller

1838073

Thu

Jan

6

19:15:52

2000

Version

8.0.0

madd-card

1336282

Thu

Jan

6

19:16:00

2000

Version

8.0.0

Configuring a MultiDSP card

When a unit detects the presence of a card in one of its slots, the unit creates default profiles appropriate for that type of card. Some default profiles might need to be reconfigured when a new card is installed in a slot.

Minimal configuration is required to set up MultiDSP services on a unit. Licensed MultiDSP services are automatically enabled. Depending on the type of MultiDSP card installed, 48 or 96 default call routes are created for each enabled service when the card is installed.

Configuration might be required for implementing VoIP MultiVoice functionality. VoIP MultiVoice configuration is described in the MultiVoice for MAX TNT Configuration Guide.

MultiDSP configuration includes the following tasks:

Verifying that the correct software licenses are loaded on the MAX TNT or APX 8000 unit and that the desired MultiDSP services are enabled. The Base profile provides this information.

Confirming that the call routes are correct for the desired MultiDSP services. The Call-Route profile controls call routing in the unit. The unit automatically generates call routes for modem calls and licensed services when a MultiDSP card is installed or when the slot -rand slot -ucommands are issued.

6-6