Bay Technical Associates V79 PDI-1, V80 PDI-2 owner manual Report Start Time

Page 29

When Schedule Reporting Method is selected, the PDI will begin reporting event samples as events occur at the programmed Report Start Time (see Section 5.1.4.2). The Report Start Time is programmable up to 24 hours in advance of the current (time-of-day) clock time. Event samples are stored in the buffer until the Report Start Time is reached at which time all buffered event samples are reported to the host module. Further reporting is based upon the selected Report Interval as explained in Section 5.1.4.3.

5.1.4.2 REPORT START TIME

By responding to the Enter Selection: message at the end of the Reporting Setup Menu on page 23 with "2" (Report Start Time), you may program the time the PDI will start reporting when using Schedule Reporting Method. The PDI will respond with the Report Start Time menu as follows:

REPORT START TIME

 

Reporting Start Time

HH:MM

Current Date and Time

MM/DD/YY HH:MM:SS

Enter Hours (0-24) <cr>, or X to Exit:

Enter Minutes (0-59) <cr>, or X to Exit:

This menu shows the current Reporting Start Time, Current Date and Time as reported by the base unit's time-of day clock when the reporting start time entry was selected, and prompts you to enter the desired Report Start Time. Reporting can be delayed up to 24 hours from the current time.

Enter the desired Report Start Time. For example, suppose the Current Time is 9:20:30 and the Reporting Start Time is set to 10:45. After you exit the Configuration Main Menu, the PDI will start reporting event samples at 10:45 at the programmed Sampling Setup. If the M Series loses power, reporting resumes the next time the designated Report Start Time is observed by the time-of day clock.

25

Image 29
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Sampling Setup USER-PROGRAMMABLE FeaturesReporting Setup Reporting MethodHost Address Report Start TimeReport Interval Terminating Characters Dynamic ConfigurationData Commands Take a single sample for Ports Clear Event Latch Data Clear Event Buffer CommandClear Event Counter Command Report Event Duration Command Report ALL Buffered Events CommandReport Event Counter Command Report Event Latch Data and Reset Command Report Event Latch Data CommandReport Event Counter and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Time TAG Command Debounce Delay CommandReporting Method Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page