Bay Technical Associates V80 PDI-2 Terminating Characters, Dynamic Configuration, Data Commands

Page 14

4.2.2.6 TERMINATING CHARACTER(S)

The Terminating Character(s) is added at the end of an event sample to match the requirements of the host terminal or application software. The Terminating Character(s) consists of one or two hexadecimal characters. The default

Terminating Characters are 0D Hex (Carriage Return) followed by 0A Hex (Line

Feed).

4.2.3DYNAMIC CONFIGURATION

You may enable or disable Dynamic Configuration for the PDI. Dynamic configuration mode allows non-verbose or "on-the-fly" configuration commands to be issued to the PDI which are summarized in Section 5.2. The default Dynamic

Configuration setting is disabled.

4.3DATA COMMANDS

You may issue PDI data commands through a host module to perform single operations while temporarily overriding the module's current operating configuration. Some data commands apply to all types of DAC modules, while others apply to specific modules. Data commands may be entered repeatedly to get specific event samples. You may issue a single data command to obtain event samples from multiple channels. Data commands must be used to obtain event samples when using Command Reporting Method.

PDI data commands are sent through a host module using the following procedure:

1.Select the PDI from the host module by sending a select sequence which consists of the port select code ($BT - default), the desired module number (2 to 16), and a terminating character of Carriage Return (0D Hex) or Line Feed (0A Hex). For example, to select an PDI Module located in slot 15 using the default port select code, send $BT15<cr>.

10

Image 14
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Installation CablingPDI-2 AC Input Setup Operation Reporting Setup USER-PROGRAMMABLE FeaturesSampling Setup Reporting MethodHost Address Report Start TimeReport Interval Terminating Characters Dynamic ConfigurationData Commands Take a single sample for Ports Clear Event Latch Data Clear Event Buffer CommandClear Event Counter Command Report Event Duration Command Report ALL Buffered Events CommandReport Event Counter Command Report Event Latch Data and Reset Command Report Event Latch Data CommandReport Event Counter and Reset Command Report a Single Buffered Event Command Event Sample ReportingPage Event Sample Presentation 115,1 1320 11/18/93 Configuration MENU-DRIVEN ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Time TAG Command Debounce Delay CommandReporting Method Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page