Table 6-1Channel configuration

Output Wiring – Model 2700 Configurable I/O Transmitters

Table 6-1Channel configuration

Channel

Terminals

Configuration options

Power

 

 

 

 

A

1 & 2

mA output with HART/Bell 202(1)

Internal

 

 

 

 

B

3 & 4

• mA output (default)

Internal

 

 

 

 

 

 

• Frequency output

Internal or external(2)

 

 

 

 

 

 

• Discrete output

Internal or external

 

 

 

 

C

5 & 6

• Frequency output (default)(3)

Internal or external

 

 

 

 

 

 

• Discrete output

Internal or external

 

 

 

 

 

 

• Discrete input

Internal or external

 

 

 

 

(1)The Bell 202 signal is superimposed on the mA output.

(2)You must provide power to the outputs when a channel is set to external power.

(3)When configured for two frequency outputs (dual pulse), frequency output 2 is generated from the same signal that is sent to the first frequency output. Frequency output 2 is electrically isolated but not independent.

Figure 6-1Configuration of configurable I/O terminals

Terminals 1 and 2 (Channel A) mA1 output

Internal power only

HART (Bell 202) communications

Terminals 3 and 4 (Channel B) mA2 output or FO or DO1 Power:

mA – internal only

FO or DO – internal or external No communications

Terminals 5 and 6 (Channel C) FO or DO2 or DI

Power: internal or external No communications

mA = milliamp

FO = frequency output DO = discrete output DI = discrete input

6.3mA output wiring

+

+

+

The following 4–20 mA wiring diagrams are examples of proper basic wiring for the Model 2700 primary and secondary mA outputs. The following options are shown:

Basic mA wiring (Figure 6-2)

HART/analog single-loop wiring (Figure 6-3)

HART multidrop wiring (Figure 6-4)

Note: If you will configure the transmitter to poll an external temperature or pressure device, you must wire the mA output to support HART communications. You may use either HART/analog single-loop wiring or HART multidrop wiring.