Specifications

Model 2700 transmitters with non-incendive FOUNDATION fieldbus outputs option board (output option code N)

One FOUNDATION fieldbus H1 output:

-FOUNDATION fieldbus wiring is non-incendive

-Manchester-encoded digital signal conforms to IEC 1158-2

Model 2700 transmitters with PROFIBUS-PA outputs option board (output option code G)

One PROFIBUS-PA output:

-PROFIBUS-PA wiring is intrinsically safe with an intrinsically safe PROFIBUS-PA network power supply

-Manchester-encoded digital signal conforms to IEC 1158-2

A.1.3 Digital communication

Model 1700/2700 transmitters support the following digital communications:

Service port

•One service port can be used for temporary connection only

•Address 111

•Uses RS-485 Modbus RTU signal, 38.4 kilobaud, one stop bit, no parity

HART/Bell202

A HART/Bell202 signal can be superimposed on the primary mA output and used for interface with a host system:

•Frequency: 1.2 and 2.2 kHz

•Amplitude: 0.8 mA peak-to-peak

•1200 baud

•Requires 250 to 600 Ohms load resistance

HART/RS485 or Modbus/RS485 (transmitters with analog outputs option board only)

One pair of terminals provides RS-485 communications:

•Can be used for direct connection to a HART or Modbus host system

•Accepts baud rates between 1200 baud and 38.4 kilobaud

FOUNDATION fieldbus or PROFIBUS-PA transmitters

One pair of terminals provides FOUNDATION fieldbus or PROFIBUS-PA communications:

•Resource, transducer, and function blocks per FOUNDATION or PROFIBUS specification

Output Wiring – Intrinsically Safe

Output Wiring – Configurable I/O Output Wiring – Fieldbus/PROFIBUS

Specifications

Installation Manual

61

Page 65
Image 65