A.4.3 Interface/display

Specifications

A.4.3 Interface/display

The transmitter may be ordered with or without a display. The characteristics of the display are as follows:

Segmented 2-line display with LCD screen with optical controls and flowmeter-status LED is suitable for hazardous area installation

-LCD line 1 lists the process variable, line 2 lists engineering unit of measure through a non-glare tempered glass lens

-Display controls feature optical switches that are operated through the glass with a red LED indicator to show that the “button” has been pressed

To facilitate various mounting orientations, the display can rotate 360° on the transmitter in 90° increments

A.4.4 Weight

For the weight of a transmitter mounted integrally with a sensor, refer to the sensor specifications.

The 4-wire remote transmitter weighs:

With display: 8 lb (3,6 kg)

Without display: 7 lb (3,2 kg)

The 9-wire remote transmitter/core processor assembly weighs:

With display: 14 lb (6,3 kg)

Without display: 13 lb (5,9 kg)

A.4.5 Dimensions

Figures A-1through A-5show the dimensions of the Model 1700 or 2700 transmitter with and without a display, the transmitter/core processor assembly with and without a display, and the stand- alone core processor. For dimensions of integrally mounted transmitters and sensors, refer to the product data sheet for your sensor.

Output Wiring – Intrinsically Safe

Output Wiring – Configurable I/O Output Wiring – Fieldbus/PROFIBUS