With time tag enabled, a MM/DD/YY HH/MM/SS entry is appended to all samples, where MM is the month, DD is the day, YY is the year, HH is the hour, MM is the minute, and SS is the second according to the base unit's time-of-day clock.

5.1.4.6 TERMINATING CHARACTER(S)

By responding to the Enter Selection: message at the end of the Reporting Setup Menu on page 26 with "7" (Terminating Character(s)), you may program one or two characters to be appended at the end of each event sample. This option allows a user to match the host terminal and/or requirements of their application software. The PDI will respond with the Enter Terminating Character menu as follows:

ENTER TERMINATING CHARACTER

Terminating Character(s)

0D0A

Enter 1 or 2 Terminating Characters in Hex Format (i.e. 0D0A for CR+LF) <cr>, or X to Exit:

Type the hexadecimal representation of the desired terminating character(s). For example, Carriage Return would be represented by 0D Hex and Line Feed would be represented by 0A Hex.

NOTE: Only ASCII characters A-F and 0-9 are acceptable.

5.1.5DYNAMIC CONFIGURATION

By responding to the Enter Selection: message at the end of the Configuration Main Menu (see Section 5.1.1) with "5" (Dynamic Configuration), you may program the PDI to respond to dynamic configuration (non-verbose) commands. The PDI will respond with the Dynamic Configuration Commands menu as follows:

DYNAMIC CONFIGURATION COMMANDS

Dynamic Configuration Commands.....DISABLED

Enable

1

Disable

2

Exit

X

Enter Selection:

 

28

Image 32
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Installation CablingPDI-2 AC Input Setup Operation USER-PROGRAMMABLE Features Sampling SetupReporting Setup Reporting MethodHost Address Report Start TimeReport Interval Terminating Characters Dynamic ConfigurationData Commands Take a single sample for Ports Clear Event Latch Data Clear Event Buffer CommandClear Event Counter Command Report Event Duration Command Report ALL Buffered Events CommandReport Event Counter Command Report Event Latch Data and Reset Command Report Event Latch Data CommandReport Event Counter and Reset Command Report a Single Buffered Event Command Event Sample ReportingPage Event Sample Presentation 115,1 1320 11/18/93 Configuration MENU-DRIVEN ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Time TAG Command Debounce Delay CommandReporting Method Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page