Bay Technical Associates V79 PDI-1, V80 PDI-2 Appendix a DATA/CONFIGURATION Command Summary

Page 37

APPENDIX A DATA/CONFIGURATION COMMAND SUMMARY

The tables below summarize the data and configuration commands supported by the V79 PDI-1 and V80 PDI-2 I/O modules:

 

V79 PDI-1 & V80 PDI-2 COMMAND SUMMARY

Command

 

Description

CBc<cr> (c=Ch# 1 to 16, 0=all)

 

Clear Event Buffer. Clear all buffered event samples.

 

 

 

CCc<cr> (c=Ch# 1 to 16, 0=all)

 

Clear Event Counter(s)

 

 

 

CRc<cr> (c=Ch# 1 to 16, 0=all)

 

Clear Event Latch Data

 

 

 

RAc<cr> (c=Ch# 1 to 16, 0=all)

 

Report All Buffered Events

 

 

 

RCc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Event Counter(s)

 

 

 

RDc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Event Duration(s)

 

 

 

RLc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Event Latch Data

 

 

 

ROc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Event Counter and Reset

 

 

 

RRc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Event Latch Data

 

 

 

RSc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Single Buffered Event (first in, first out)

 

 

 

SAc<cr> (c=Ch# 1 to 16, 0=all)

 

Read and report the current state of the selected input(s).

 

 

 

SLc<cr> (c=Ch# 1 to 16, 0=all)

 

Report Latest Event

 

 

 

* Multiple channels are selected using 4 formats.

Examples: SA1,2,3,4,5,6,7,8<cr>, SA1-8<cr>,SA0<cr>, SA1,2,4-8<cr>

V79 PDI-1 & V80 PDI-2 DYNAMIC CONFIGURATION COMMAND SUMMARY

Command

Description

DBn<cr> (n=0-65535ms)

Debounce Delay

 

 

DFn<cr> (n=1 or 2)

Data Format. 1=Hexadecimal and 2=Decimal.

 

 

RMn<cr> (n=1 to 3)

Reporting Method. 1=Command, 2=Immediate, and 3=Schedule.

 

 

TTn<cr> (n=1 or 2)

Time Tag. 1=Enable and 2=Disable.

 

 

33

Image 37
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Sampling Setup USER-PROGRAMMABLE FeaturesReporting Setup Reporting MethodReport Interval Report Start TimeHost Address Data Commands Dynamic ConfigurationTerminating Characters Take a single sample for Ports Clear Event Counter Command Clear Event Buffer CommandClear Event Latch Data Report Event Counter Command Report ALL Buffered Events CommandReport Event Duration Command Report Event Counter and Reset Command Report Event Latch Data CommandReport Event Latch Data and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Reporting Method Command Debounce Delay CommandTime TAG Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page