Bay Technical Associates V80 PDI-2 owner manual V79 PDI-1 Module

Page 6

1.1V79 PDI-1 MODULE

The main features of the V79 PDI-1 module are sixteen microprocessor-controlled input channels that can be connected with individual ground returns, or a common single-point ground. The input channels provide a flexible, reliable method to detect and report the change-in-state of a circuit. The change can be from infinite resistance (open) to continuity (closed), and vice versa. For example, the change- in-state could be for a set of form C (dry) relays or switch contacts. Any change in the status of individual or multiple inputs may be observed, recorded, reported, analyzed, and acted upon. The level and type of actions desired or required are easily selectable through the PDI-1's configuration menu.

Individual or multiple inputs may be polled for present status or configured to automatically provide an alert message when a change-in-state is observed. Momentary changes in an input's condition can be monitored and "latched" into memory for post-action analysis. The reporting of false, or transient events can be prevented by selection of programmable "debounce times". Input connections to the PDI-1 are made through a standard DC-37F connector.

1.2V80 PDI-2 MODULE

The primary feature of the PDI-2 series is sixteen microprocessor controlled, optically isolated voltage inputs. The PDI-2A is designed for an input "on" voltage range of 5 to 24 AC or DC volts and the PDI-2B for 100 to 130 AC or DC volts. All inputs have 500V AC or DC electrical isolation from ground. Inputs are not polarity sensitive. Therefore, paired signal inputs can be made using the "return" or "input" terminal as the positive connection.

A mixture of AC and DC inputs can be selected by individual channels. For example, Channel 1 could be a DC input, Channels 2 and 3 AC inputs, Channel 4 a DC input, etc.. Dip switches are provided for selection of low-pass filtering during AC input operation.

2

Image 6
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Installation CablingPDI-2 AC Input Setup Operation Reporting Setup USER-PROGRAMMABLE FeaturesSampling Setup Reporting MethodReport Start Time Report IntervalHost Address Dynamic Configuration Data CommandsTerminating Characters Take a single sample for Ports Clear Event Buffer Command Clear Event Counter CommandClear Event Latch Data Report ALL Buffered Events Command Report Event Counter CommandReport Event Duration Command Report Event Latch Data Command Report Event Counter and Reset CommandReport Event Latch Data and Reset Command Report a Single Buffered Event Command Event Sample ReportingPage Event Sample Presentation 115,1 1320 11/18/93 Configuration MENU-DRIVEN ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Debounce Delay Command Reporting Method CommandTime TAG Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page