Bay Technical Associates V79 PDI-1, V80 PDI-2 owner manual Installation, Cabling

Page 9

3 INSTALLATION

The PDI-1 and PDI-2 are installed in the M Series chassis as described in Section

3.5of the base unit operator's manual.

NOTE: The PDI-1 or PDI-2 cannot be installed as Module 1. If an PDI-1 or PDI- 2 is removed from a module slot and a different PDI-1 or PDI-2 is installed in that location, the newly installed module acquires the previous module's configuration.

Moving an PDI-1 or PDI-2 to a different module location requires reconfiguration because the configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module.

3.1CABLING

The V79 PDI-1 and V80 PDI-2 modules each have a DC-37F connector. Equipment connections for each module is similar. Each input of the V79 module has a ground connection and each input of the V80 module has a return connection. Figure 1 and Figure 2 below show the V79 and V80 connections respectively.

Circuit

Pin #

Circuit

 

Circuit

Pin # Circuit

Connection

 

Connection

Connection

Connection

 

￿￿￿￿￿￿￿￿

 

￿￿￿￿￿￿￿￿

 

Input

#1 ￿1

20￿ Ground #10

Input

#1 ￿1

20￿ Return #10

Ground #1 ￿2

 

21￿ Input #11

Return #1 ￿2

21￿ Input

#11

Input

#2 ￿3

22￿ Ground #11

Input

#2 ￿3

22￿ Return #11

Ground #2 ￿4

 

23￿ Input #12

Return #2 ￿4

23￿ Input

#12

Input

#3 ￿5

24￿ Ground #12

Input

#3 ￿5

24￿ Return #12

Ground #3 ￿6

 

25￿ Input #13

Return #3 ￿6

25￿ Input

#13

Input

#4 ￿7

26￿ Ground #13

Input

#4 ￿7

26￿ Return #13

Ground #4 ￿8

 

27￿ Input #14

Return #4 ￿8

27￿ Input

#14

Input

#5 ￿9

28￿ Ground #14

Input

#5 ￿9

28￿ Return #14

Ground #5 ￿10

29￿ Input #15

Return #5 ￿10

29￿ Input

#15

Input

#6 ￿11

30￿ Ground #15

Input

#6 ￿11

30￿ Return #15

Ground #6 ￿12

31￿ Input #16

Return #6 ￿12

31￿ Input

#16

Input

#7 ￿13

32￿ Ground #16

Input

#7 ￿13

32￿ Return #16

Ground #7 ￿14

33￿ N.C.

Return #7 ￿14

33￿ N.C.

Input

#8 ￿15

34￿ N.C.

Input

#8 ￿15

34￿ N.C.

Ground #8 ￿16

35￿ N.C.

Return #8 ￿16

35￿ N.C.

Input

#9 ￿17

36￿ N.C.

Input

#9 ￿17

36￿ N.C.

Ground #9 ￿18

37￿ N.C.

Return #9 ￿18

37￿ N.C.

Input #10 ￿19

￿

 

Input #10 ￿19 ￿

￿￿￿￿￿￿￿￿

 

￿￿￿￿￿￿￿￿

Figure 1:

V79

Input Connections

Figure 2: V80 Input Connections

5

Image 9
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Sampling Setup USER-PROGRAMMABLE FeaturesReporting Setup Reporting MethodReport Start Time Report IntervalHost Address Dynamic Configuration Data CommandsTerminating Characters Take a single sample for Ports Clear Event Buffer Command Clear Event Counter CommandClear Event Latch Data Report ALL Buffered Events Command Report Event Counter CommandReport Event Duration Command Report Event Latch Data Command Report Event Counter and Reset CommandReport Event Latch Data and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Debounce Delay Command Reporting Method CommandTime TAG Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page