1 GENERAL

BayTech's PDI modules are designed for use with the M16 and M8 (DAC) Data Acquisition Controllers. Both modules are used to detect events where an event is defined as a change-in-state of an input and return to the original state. The V79 PDI-1 module is used for the detection of switch closure in applications requiring notification of device status such as burglar alarms, fire alarms, event counters and timers, process control, etc.. The V80 PDI-2 is used for the detection of optically isolated voltage inputs in applications requiring industrial control of motors, process monitoring, limit switch status, and the monitoring of relay status.

All events detected by either module are recorded as an event sample and sent to a host computer/controller connected to a V71 host module. The current status of input channels may be provided to the host computer/controller upon request. Event samples or input channel status may be provided with a "time stamp" or "Time Tag" which is available through the use of a "time-of-day" clock located in the M16/M8 base unit. A time tag includes the month, day, year, hour, minute and second the event occurred or the input channel status was taken.

Event status is supplied to the host computer/controller in one of the following modes:

1)Upon user request (COMMAND).

2)At a specific date/time (SCHEDULE).

3)Real time reporting of events (i.e., as events occur IMMEDIATE).

1

Image 5
Contents BayTech Publication #U140E105 Page Table of Contents Reporting Method General V79 PDI-1 Module Specifications V79 PDI-1 Switch Input Status Module V80 PDI-2 Optically Isolated Input Module Cabling InstallationPDI-2 AC Input Setup Operation Sampling Setup USER-PROGRAMMABLE FeaturesReporting Setup Reporting MethodHost Address Report Start TimeReport Interval Terminating Characters Dynamic ConfigurationData Commands Take a single sample for Ports Clear Event Latch Data Clear Event Buffer CommandClear Event Counter Command Report Event Duration Command Report ALL Buffered Events CommandReport Event Counter Command Report Event Latch Data and Reset Command Report Event Latch Data CommandReport Event Counter and Reset Command Event Sample Reporting Report a Single Buffered Event CommandPage Event Sample Presentation 115,1 1320 11/18/93 MENU-DRIVEN Configuration ConfigurationPage Configuration Main Menu Module Status SET Latch Polarity Select Reporting Method Report Start Time Report Interval Enable / Disable Time Tagging Dynamic Configuration Commands Exit Dynamic Configuration Procedure and Commands Time TAG Command Debounce Delay CommandReporting Method Command Front Panel Configuration Appendix a DATA/CONFIGURATION Command Summary Appendix B Eprom Upgrade Appendix C V79 PDI-1 Mechanical Layout Page Page Appendix D V80 PDI-2 Mechanical Layout Page Page Appendix E Index Fifo Page