A# Area O/C

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 45

A# Area O/C

Default:

Yes

Selection:

Yes or No

Ye

Include the Area # and generate Opening

s

and Closing Reports for this area when it is

 

armed.

 

 

 

No

Do not include the Area # or generate

 

Opening and Closing Reports for this area.

 

 

 

Determines if the area number and the account number are reported at arming and disarming. As long as Account O/C is No, the account number sends a report when arming this area individually. If Account O/C is Yes, all areas with the same account number must also be armed.

An Area Opening Report is generated when each area is opened (disarmed). An Area Closing Report is generated when each individual area is closed (armed).

Do not program this item as Yes if the control panel reports to an automation system that cannot interpret multiple Area Opening and Closing Reports.

A# Disable O/C in Window

Default: Yes

Selection: Yes or No

Yes

Do not send Opening and Closing Reports

 

to the central station if they occur inside an

 

active window.

 

If an Opening or Closing Report occurs

 

outside a window, send it with an early or

 

late modifier. Refer to Section 5.1.1

 

Opening and Closing on page 106.

 

The active window must be a Closing

 

Window for Closing Reports. It must be an

 

Opening Window for Opening Reports.

 

 

No

Send Opening and Closing Reports to the

 

central station even when they occur inside

 

a programmed window. If an opening or

 

closing occurs outside of the appropriate

 

window, it reports but does not have an

 

early or late modifier.

 

If you want to monitor all opening and

 

closing activity and use features provided

 

by Opening and Closing Windows, program

 

this item as No, and program the

 

appropriate O/C Windows.

 

 

Determines if opening and closing activity is reported when it occurs inside an Opening or Closing Window, as programmed in O/C Windows.

Reports are always logged and printed on a local printer, if installed.

A# Auto Close

Default: No

Selection: Yes or No

Ye The area automatically master arms at the

send of the Close Window.

When the area is armed automatically, a Closing Report is sent if the Area or Account Reports are programmed to do so.

No Do not automatically arm the area at the end of the Close Window.

With this program item, the control panel can automatically master arm the area at the end of the Closing Window regardless of the previous armed state.

When an area master arms automatically at the end of a Close window, the system disregards the settings in A# Force Arm Max and P## Bypassable for any faulted points. The faulted points arm when they return to normal state.

A# Fail to Open

Default:

 

No

 

 

 

Selection:

 

Yes or No

Yes

 

Fail to Open Report is sent for this

 

 

area if the area was not disarmed

 

 

when the Opening Window stop time

 

 

occurred.

No

 

Fail to Open Report is not sent for

 

 

this area.

 

 

 

Use to determine if a Fail to Open Report is sent for this area. This can determine if a user failed to disarm the area before the Opening Window expiring. Normal Opening and Closing Reports do not need to be programmed to use this feature.