A# Fail to Close

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 46

A# Fail to Close

Default:

No

Selection:

Yes or No

Yes

Fail to Close Report is sent for this

 

area if the area is not armed when

 

the Closing Window stop time occurs.

 

Note:

 

Program an exit delay time in

 

Exit Dly Time.

 

 

No

Fail to Close Report is not sent for

 

this area.

 

• If Auto Close is programmed

 

Yes, a Fail to Close Report is

 

sent because it occurs when the

 

Closing Window stop time

 

occurred.

 

• If Disable O/C in Window is

 

Yes, the Fail to Close Report is

 

followed by Closing Late or

 

F(orce) Close Late.

 

 

This item determines if a Fail to Close Report is sent for this area. Use to determine if a user failed to arm the area before the Closing Window expires. Normal Opening and Closing Reports do not need to be programmed to use this feature.

A# Restrictd O/C

Default:

 

No

Selection:

 

Yes or No

Yes

 

Restrict Opening and Closing

 

 

Reports for this area. A# Area O/C

 

 

must be programmed Yes to

 

 

generate Restricted Opening and

 

 

Closing Reports.

 

 

Note:

 

 

If a passcode is not required for

 

 

arming or disarming and this item

 

 

is Yes, the area sends only

 

 

Restricted Opening and Closing

 

 

Reports. In this case, Restricted

 

 

Reports are sent without User ID.

 

 

Opening/Closing Window does not

 

 

affect this report. Windows do not

 

 

prevent sending Restricted Opening

 

 

and Closing Reports from being sent.

 

 

Early or late designations are not

 

 

added to Opening or Closing Reports

 

 

when they are sent according to the

 

 

rules for Restricted Opening or

 

 

Closing Reports.

No

 

Do not Restrict Opening and Closing

 

 

Reports for this area.

 

 

Regardless of programming in

 

 

Authority Levels L## Restricted O/C,

 

 

reports are not restricted in this area

 

 

when this item is programmed as No.

 

 

Note:

 

 

Was Force Armed and Forced

 

 

Close Events can still be sent to

 

 

the central station if enabled in

 

 

Routing when force arming the

 

 

system.

 

 

 

This item determines if this area can restrict Opening and Closing Report activity.

A Restricted Opening Report refers to the control panel sending an Area Opening Report only when the area is disarmed after a non-fire alarm.

A Restricted Closing Report refers to the control panel sending a Force Closed Report only when the area was master armed with Controlled points that were faulted during the arming sequence. The sequence of reports generated by a restricted closing is: Was Force Armed, Forced Point, and Force Closed.