Bosch Appliances D9412GV2 manual Enable Ext Modem, Seize Relay, Modem Init String, RPS Dial String

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 134
Image 134
Enable Ext Modem

D9412GV2/D7412GV2 Program Entry Guide 6.0 GV2AUX

EN 134

Enable Ext Modem

Default:

No

Selection:

Yes or No

Yes

Enable SDI Address 88 for use with

 

an external modem.

 

 

No

Disable SDI Address 88 for use with

 

an external modem.

 

 

Setting this item to Yes instructs the control panel that SDI Address 88 is enabled for use with an external modem. For further information on Local RPS programming, refer to the RPS Installation and Operation Guide (P/N: 4998141259).

Setting this item to Yes disables Enhanced Communication and SDI RPS for use over a LAN or WAN.

Answer Armed

Default:

7

Selection:

0 to 15

0

No answer when all areas are

 

Master Armed.

 

 

0 to 15

The control panel answers the

 

phone after the specified number of

 

rings when all areas are Master

 

Armed.

 

 

Determines the number of rings after which the external modem automatically answers a call if all areas are Master Armed.

Answer Disarmed

Default:

7

Selection:

0 to 15

0

No answer when any area is

 

Perimeter Armed or Disarmed.

 

 

0 to 15

The control panel answers the

 

phone after the specified number of

 

rings when any area is Perimeter

 

Armed or Disarmed.

 

 

Determines the number of rings after which the external modem automatically answers a call if any area is Perimeter Armed or Disarmed.

RPS Line Monitor

Default: No

Selection: Yes or No

Not used. Keep this item set to No.

Seize Relay

Default: No

Selection: Yes or No

Not used. Keep this item set to No.

Modem Init String

Default:

ATE0

Selection:

A to Z (capital letters only), 0 to 9,

 

[SPACE], ! “ # $ % & ‘ ( ) * + , - . / :

 

; < = > ? @ [ \ ] ^ _

 

 

Determines which initialization string the control panel sends to the external modem when the control panel powers up.

If special characters are required, Modem Init String can be programmed successfully only from RPS. The D5200 Programmer allows only the characters shown in the Modem Init String default selections.

RPS Dial String

Default: ATDT

Selection: Not available

Not used.

Bosch Security Systems, Inc. 10/08 F01U003636-04