Bosch Appliances D9412GV2 manual A# Area Type, Default, Regular, Selection

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 40
Image 40
A# Area Type

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 40

A# Area Type

Default:

Regular

Selection:

Regular, Master, Associate, or Shared

Regular

Arms or disarms as an independent area.

 

 

 

 

 

Master

Does not allow arming for this area unless all associate areas with the same A# account

 

number are master exit delay armed or master armed. CHK AREA displays if the associate

 

areas are not armed. Exception: RPS allows master areas to be armed without all associate

 

areas being in the armed state.

 

A master area can be disarmed regardless of the armed state of the other areas in the account.

 

Multiple master areas can be programmed in a single account.

 

 

 

 

 

 

 

 

CC# Scope affects master arming.

 

 

 

 

 

 

 

 

 

 

Area: When arming a master area that has CC# Scope set to Area for all

 

 

 

 

 

 

 

keypads, all associate areas within the same account must first be armed

 

 

 

 

independently by other means.

 

 

 

 

Panel Wide or Account Wide: When arming a master area from a keypad

 

 

 

 

with CC# Scope set to Panel Wide or Account Wide, all associate areas

 

 

 

 

enters exit delay as soon as the master area is armed. If there is a shared

 

 

 

 

area within the same account, it begins its exit delay after all associate

 

 

 

 

areas are armed.

 

 

 

 

 

 

 

 

 

Using the arming sked (S## Function 1) requires that you first use an

 

 

 

 

 

 

 

 

 

 

arming sked to arm the associate areas before using an arming sked to

 

 

 

 

arm the master area. Arming master areas with RPS, Keyswitch, or Auto

 

 

 

 

 

 

 

Close parameters (refer to Section 2.9.5 Open/Close Options on page 43)

 

 

 

 

occurs before all associate areas are armed

 

 

 

 

 

 

Associate

Allows arming and disarming regardless of the armed state of the other areas with the same A#

 

account number. Use this area type with a master area and associate it by using the same

 

account number.

 

 

 

 

 

 

 

 

 

 

 

 

 

Keypads assigned to associate areas, when used with shared areas, must

 

 

 

 

have CC# Scope programmed.

 

 

 

 

 

 

 

 

 

 

 

Shared

Shared areas cannot be armed using a passcode, key switch, token or card, sked, or RPS.

 

 

 

 

 

 

 

 

The scope of all associate areas must include the shared area(s) in order to view

 

 

 

 

 

 

 

 

 

 

 

 

faulted points.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 40
Image 40
Bosch Appliances D9412GV2 manual A# Area Type, Default, Selection, Regular, Master, Associate, or Shared