Bosch Appliances D9412GV2 manual C Function 128 through, Authority Level, L## Disarm

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 67
Image 67
C Function 128 [through 143]

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 67

Custom Functions

C Function 128 [through 143]

Default:

E

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

128 through

Enable Custom

(Menu function

143

Functions 128

only)

 

through 143

 

When enabled, Custom Function determines if a pass code is required when accessing a custom function from the menu list. ENTER PASSCODE (or Enter Passcode + Enter Key on the D1260) appears when this function is pass-code protected. If a command within the Custom Function is pass-code protected, the keypad displays ENTER PASSCODE (or Enter Passcode + Enter Key on the D1260) and waits for the user to enter a valid pass code before proceeding with the rest of the Custom Function. If a pass code is not entered within 10 sec, the Custom Function times out and the display returns to idle text.

2.11.4 Authority Level Selections

Use Section 2.11.4 Authority Level Selections on page 67 to determine which Authority Level can access keypad functions that are pass-code protected. Selecting Enable items in the Authority Level section is not necessary if the keypad function is disabled or enabled. Each individual function has two selections you can use for the authority level you are programming.

Press the [SPACE] bar to scroll through the selections. Press [ENTER] when the correct selection appears in the display.

Table 28: Authority Level Selections

Authority

Description

Level

 

Blank

Disabled: This function is not

 

authorized for the user who is

 

assigned this authority level.

EEnabled: This function is authorized for the user who is assigned this authority level.

Authority Level

Default: 1

Selection: 1 to 14

Enter the number of the authority level you want to program. Authority Level 15 (Service Passcode) cannot be edited.

To determine the L## default values on pages 67 through 76, refer to the User Interface section for the GV2MAIN Handler in the program record sheet.

L## Disarm

Default:

 

Refer to the program record sheet

Selection:

 

Blank or E

 

 

 

Function

 

Function Name

No.

 

 

1

 

Disarm

Use the disarming function to disarm areas that are master armed or perimeter armed. If enabled, the following disarming choices are available to the user with this authority:

DISARM ALL: Disarms all areas within the CC# Scope of the keypad being used by accessing the Function Menu and the authority level of the user performing the function.

DISARM AREA: Disarms only the displayed area.

Many options are available for arming and disarming. Selecting an option depends on A# Area Type and CC# Scope. Read the definitions of area type in Section 2.9 Area Parameters on page 5 and CC# Scope in Section 2.10.1 Keypad (Command Center) Assignment on page 51.

Bosch Security Systems, Inc. 10/08 F01U003636-04